Pusat Pengajian Sains Kimia, Universiti Sains Malaysia, 11800 USM Pulau Pinang, Malaysia.
Biosens Bioelectron. 2012 Jan 15;31(1):433-8. doi: 10.1016/j.bios.2011.11.007. Epub 2011 Nov 16.
The electrochemical biosensors based on poly(o-phenylenediamine) (PoPD) and acetylcholinesterase (AChE) and choline oxidase (ChO) enzymes were fabricated on carbon fibre (CF) substrate. The electropolymerized PoPD was used to reduce the interfering substances. The electrode assembly was completed by depositing functionalized carbon nano tubes (FCNTs) and Nafion (Naf). Amperometric detection of acetylcholine (ACh) and choline (Ch) were realized at an applied potential of +750 mV vs Ag/AgCl (saturated KCl). At pH 7.4, the final assembly, Naf-FCNTs/AChE-ChO((10:1))/PoPD/CF(Elip), was observed to have high sensitivity towards Ch (6.3±0.3 μA mM(-1)) and ACh (5.8±0.3 μA mM(-1)), linear range for Ch (K(M)=0.52±0.03 mM) and ACh (K(M)=0.59±0.07 mM), and for Ch the highest ascorbic acid blocking capacity (97.2±2 1mM AA). It had a response time of <5s and with 0.045 μM limit of detection. Studies on different ratio (ACh/Ch) revealed that 10:1, gave best overall response.
基于聚邻苯二胺(PoPD)和乙酰胆碱酯酶(AChE)和胆碱氧化酶(ChO)酶的电化学生物传感器在碳纤维(CF)基底上制造。电聚合的 PoPD 用于减少干扰物质。电极组件通过沉积功能化的碳纳米管(FCNTs)和 Nafion(Naf)完成。在 +750 mV 相对于 Ag/AgCl(饱和 KCl)的应用电位下,实现了乙酰胆碱(ACh)和胆碱(Ch)的安培检测。在 pH 7.4 下,最终组件 Naf-FCNTs/AChE-ChO((10:1))/PoPD/CF(Elip) 对 Ch(6.3±0.3 μA mM(-1)) 和 ACh(5.8±0.3 μA mM(-1)) 具有高灵敏度,Ch 的线性范围为 K(M)=0.52±0.03 mM,ACh 的线性范围为 K(M)=0.59±0.07 mM,并且对 Ch 的抗坏血酸阻断能力最高(97.2±2 1mM AA)。它的响应时间<5s,检测限为 0.045 μM。对不同比率(ACh/Ch)的研究表明,10:1 给出了最佳的整体响应。