Avetisov S É, Mamikonian V R, Egorova G B, Savochkina O A
Vestn Oftalmol. 2011 Sep-Oct;127(5):3-6.
Comparative analysis of functional results of contact lens correction and penetrating keratoplasty (PKP) in keratoconus are presented. To assess resolution ability we considered visual acuity and contrast sensitivity. 117 patients (219 eyes) with stage I-IV keratoconus, wearing rigid gas-permeable contact lenses (RPCL), and 60 patients (64 eyes) after PKP were examined. In 69% patients after PKP non-corrected visual acuity (NCVA) was 0.1 or more and mean best corrected visual acuity (BCVA) was 0.63, that is similar to efficacy of contact lens correction in stage III-IV keratoconus. In 31% patients NCVA after PKP was less than 0.1 due to significant refractive arrow, visual rehabilitation of these patients required use of RPCL or refractive surgery. Contrast sensitivity in medium frequencies after PKP was almost similar to that of contact lens correction in stage III keratoconus, and in high frequencies it was close to that of stage IV.
本文对圆锥角膜患者使用角膜接触镜矫正和穿透性角膜移植术(PKP)的功能结果进行了比较分析。为评估矫正效果,我们考虑了视力和对比敏感度。对117例(219只眼)I-IV期圆锥角膜患者(佩戴硬性透气性角膜接触镜[RPCL])以及60例(64只眼)PKP术后患者进行了检查。PKP术后69%的患者未矫正视力(NCVA)为0.1或更高,平均最佳矫正视力(BCVA)为0.63,这与III-IV期圆锥角膜患者使用角膜接触镜矫正的效果相似。31%的PKP术后患者由于明显的屈光不正,NCVA低于0.1,这些患者的视力康复需要使用RPCL或屈光手术。PKP术后中频的对比敏感度与III期圆锥角膜患者使用角膜接触镜矫正的情况几乎相似,高频时则接近IV期的情况。