Suppr超能文献

带领圈和直形远端固定槽的第二代非骨水泥股骨假体的长期随访结果。

Long-term follow-up results of a second-generation cementless femoral prosthesis with a collar and straight distal fixation channels.

机构信息

Department of Orthopaedic Surgery, Yonsei University College of Medicine, Seoul, Korea.

出版信息

Yonsei Med J. 2012 Jan;53(1):186-92. doi: 10.3349/ymj.2012.53.1.186.

Abstract

PURPOSE

We evaluated the results of more than 10 years of follow-up of total hip arthroplasty using a second-generation cementless femoral prosthesis with a collar and straight distal fixation channels.

MATERIALS AND METHODS

One hundred five patients (129 hips) who underwent surgery between 1991 and 1996 for primary total hip arthroplasty using cementless straight distal fluted femoral stems were followed for more than 10 years. Ninety-four hips in 80 patients were available for clinical and radiologic analysis. The mean age at the time of surgery was 47 years, and the mean duration of follow-up was 14.3 years.

RESULTS

The mean Harris hip scores had improved from 58 points to 88 points at the time of the 10-year follow-up. Activity-related thigh pain was reported in nine hips (10%). At the last follow-up, 93 stems (99%) were biologically stable and one stem (1%) was revised because of loosening. No hip had distal diaphyseal osteolysis. Proximal femoral stress-shielding was reported in 86 hips (91%). We found no significant relationship between collar-calcar contact and thigh pain, stem fixation status, or stress-shielding. The cumulative survival of the femoral stem was 99% (95% confidence interval, 98-100%) after 10 years.

CONCLUSION

The long-term results of total hip arthroplasty using a second-generation cementless femoral prosthesis with a collar and straight distal fixation channels were satisfactory; however, the high rate of proximal stress-shielding and the minimal effect of the collar indicate the need for some changes in the stem design.

摘要

目的

我们评估了使用带领圈和直形远端固定通道的第二代非骨水泥股骨假体进行全髋关节置换术超过 10 年的随访结果。

材料和方法

1991 年至 1996 年间,105 例(129 髋)患者接受了非骨水泥直形远端有槽股骨柄初次全髋关节置换术,随访时间超过 10 年。80 例患者中的 94 髋可进行临床和影像学分析。手术时的平均年龄为 47 岁,平均随访时间为 14.3 年。

结果

在 10 年随访时,平均 Harris 髋关节评分从 58 分提高到 88 分。9 髋(10%)报告有与活动相关的大腿痛。最后一次随访时,93 枚(99%)柄(1%)因松动而被修改,没有髋发生远端骨干骨溶解。86 髋(91%)报告有股骨近端应力遮挡。我们发现领圈-小粗隆接触与大腿痛、柄固定状态或应力遮挡之间无显著关系。10 年后股骨柄的累积生存率为 99%(95%置信区间,98%-100%)。

结论

使用带领圈和直形远端固定通道的第二代非骨水泥股骨假体进行全髋关节置换术的长期结果令人满意;然而,近端应力遮挡率高和领圈效果最小表明需要对柄的设计进行一些改变。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/2940/3250326/a120b6f71f22/ymj-53-186-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验