Sabhlok Samrat, Waknis Pushkar, Bhagwat Ajit
J Maxillofac Oral Surg. 2010 Dec;9(4):339-43. doi: 10.1007/s12663-010-0128-2. Epub 2011 Jan 19.
The present study aimed to evaluate the efficacy and stability of 2.0 mm Titanium plates in treatment of mandibular angle fractures.
A randomized, prospective study was carried out on 17 patients treated by ORIF with 2.0 mm titanium plates. Operative handling of the plate and clinical stability were qualitatively analyzed.
The 2.0 mm plate showed good intra-operative handling and adequate clinical stability with follow up of 6 months showing good soft tissue healing.
A single 2.0 mm titanium plate provides easy handling and adequate occlusal stability in the post-operative phase as compared to the traditional 2.5 mm plate without post-operative MMF.
The online version of this article (doi:10.1007/s12663-010-0128-2) contains supplementary material, which is available to authorized users.
本研究旨在评估2.0毫米钛板治疗下颌角骨折的疗效和稳定性。
对17例接受2.0毫米钛板切开复位内固定治疗的患者进行了一项随机前瞻性研究。对钛板的手术操作和临床稳定性进行了定性分析。
2.0毫米钛板在术中操作良好,临床稳定性充足,随访6个月显示软组织愈合良好。
与传统的2.5毫米钛板相比,单一的2.0毫米钛板在术后阶段操作简便,咬合稳定性良好,无需术后颌间固定。