Rappaport W, Allen R, Chvapil M, Benson D, Putnam C
University of Arizona Medical Center, Tucson 85724.
Am Surg. 1990 Oct;56(10):618-23.
A new technique for placement of retention sutures is described. Twenty-five rats underwent midline laparotomy incision. The control group was closed with traditional placement of through-and-through retention sutures placed in a perpendicular direction to the wound. The experimental group was closed with retention sutures placed in a parallel direction to the wound as described below. Wound bursting strength was significantly (P less than 0.001) greater at one to five days in the experimental group compared with the control animals. In addition, inflammatory reaction and pressure necrosis were greater in the control group. It appears that parallel placement of sutures has less of a tendency to cut through tissue when subjected to the distracting forces on a midline wound.
本文描述了一种放置保留缝线的新技术。25只大鼠接受了中线剖腹切口手术。对照组采用传统的贯穿式保留缝线进行缝合,缝线与伤口垂直放置。实验组则按照如下所述,采用与伤口平行的保留缝线进行缝合。与对照组动物相比,实验组在术后1至5天的伤口破裂强度显著更高(P小于0.001)。此外,对照组的炎症反应和压迫性坏死更为严重。当受到中线伤口上的牵拉力时,缝线平行放置似乎较少有切割组织的倾向。