Istituto di Radiologia, Università di Verona, Policlinico G.B. Rossi, Piazzale L.A. Scuro, 37134, Verona, Italy.
Radiol Med. 2012 Mar;117(2):282-92. doi: 10.1007/s11547-011-0774-6. Epub 2012 Jan 7.
This retrospective study was done to correlate a quantitative assessment of the pancreatic exocrine reserve by dynamic secretin magnetic resonance cholangiopancreatography (MRCPQ) with the faecal elastase-1 (FE-1) test in patients with chronic pancreatitis.
Thirty-five patients with a clinical diagnosis of chronic (CP) or acute recurrent (ARP) pancreatitis were enrolled. FE-1 was indicative of the pancreatic exocrine reserve. Subsequently, the patient population was subdivided into two groups according to a clinical threshold value of 200 μg/g. All patients underwent MRCP examination during secretin administration. Duodenal filling volume was calculated on T2-weigthed rapid acquisition with relaxation enhancement (RARE) MRCP images obtained 10 min after secretin injection. Duodenal filling volumes were compared with FE-1 values. Scatter plots, Pearson correlation coefficient and the Mann-Whitney U test were performed.
Thirty-five paired MRCPQ-FE1 data sets were analysed. MRCPQ was significantly different (p=0.007) between patients with impaired and preserved pancreatic function; median and interquartile range (IQR) were 150.7 ml (137.3-205.5 ml; n=9) and 332.4 ml (190.6-506.9 ml; n=26). Both Pearson correlation coefficient (p<0.001) and the Mann-Whitney U test (p=0.007) were significant.
MRCPQ significantly correlates with FE-1 values. It is possible to discriminate impaired and preserved pancreatic exocrine function using MRCPQ.
本回顾性研究旨在通过动态促胰液素磁共振胆胰管成像(MRCPQ)对胰腺外分泌储备的定量评估与慢性胰腺炎患者粪便弹性蛋白酶-1(FE-1)试验相关联。
纳入 35 例临床诊断为慢性(CP)或复发性急性胰腺炎(ARP)的患者。FE-1 是胰腺外分泌储备的指标。随后,根据临床 200μg/g 的阈值将患者人群分为两组。所有患者均在给予促胰液素后行 MRCP 检查。在促胰液素注射后 10 分钟,通过 T2 加权快速获取弛豫增强(RARE)MRCP 图像计算十二指肠充盈量。比较十二指肠充盈量与 FE-1 值。进行散点图、皮尔逊相关系数和曼-惠特尼 U 检验。
分析了 35 对 MRCPQ-FE1 数据集。MRCPQ 在胰腺功能受损和正常患者之间存在显著差异(p=0.007);中位数和四分位数范围(IQR)分别为 150.7ml(137.3-205.5ml;n=9)和 332.4ml(190.6-506.9ml;n=26)。皮尔逊相关系数(p<0.001)和曼-惠特尼 U 检验(p=0.007)均有显著意义。
MRCPQ 与 FE-1 值显著相关。通过 MRCPQ 可以区分胰腺外分泌功能受损和正常。