Suppr超能文献

一种用于脊柱侧弯Cobb角的智能手机辅助测量方法的可靠性分析

Reliability analysis of a smartphone-aided measurement method for the Cobb angle of scoliosis.

作者信息

Qiao Jun, Liu Zhen, Xu Leilei, Wu Tao, Zheng Xin, Zhu Zezhang, Zhu Feng, Qian Bangpin, Qiu Yong

机构信息

Spine Surgery, Drum Tower Hospital, Nanjing University Medical School, Nanjing, China.

出版信息

J Spinal Disord Tech. 2012 Jun;25(4):E88-92. doi: 10.1097/BSD.0b013e3182463964.

Abstract

STUDY DESIGN

A comparison between the smartphone-aided measurement method and the manual measurement method for the Cobb angle in adolescent idiopathic scoliosis.

OBJECTIVE

To evaluate the reliability and measurement error for the smartphone-aided Cobb angle measurement method and compare its reliability and measurement error with those of the manual method.

SUMMARY OF BACKGROUND DATA

The development of smartphones has provided new opportunities that integrate mobile technology into daily clinical practice. Smartphone applications can provide quick assistance in the diagnosis and treatment of disease. Cobbmeter is a smartphone application designed for the measurement of Cobb angle on Apple iPhone smartphones. There is no study on the reliability and measurement error of this smartphone-aided measurement method.

METHODS

: Fifty-three posteroanterior radiographs of adolescent idiopathic scoliosis patients with thoracic scoliosis were used for the standard Cobb method of measurement (manual set) and the smartphone-aided Cobb method of measurement (smartphone set). Five spinal surgeons measured the Cobb angle with the use of both the manual method and the smartphone-aided method. The measurement time was recorded for every measurement. The frequency and the cumulative percent distribution for intraobserver differences were tabulated, both for the individual examiners and for the overall results for the 5 examiners. The intraclass correlation coefficient (ICC) 2-way mixed model on absolute agreement was used to analyze measurement reliability. Summary statistics from analyses of variance calculations were used to provide 95% prediction limits for the error in measurements. A paired t test was used to compare the time consumed for the measurement between both sets.

RESULTS

The intraobserver and interobserver ICCs were excellent in the smartphone set and in the manual set. Both the intraobserver ICC and the interobserver ICC were better in the smartphone set than in the manual set. The mean Cobb angle of all measured x-rays was 29.3 degrees (range, 17-58 degrees) in the manual set and 29.1 degrees (range, 18-56 degrees) in the smartphone set. The mean time consumed was 13.7 seconds (range, 8.6-18.5 s) for the smartphone set, whereas it was 37.9 seconds (range, 30.1-46.9 s) for the manual set, and the mean time consumed for the smartphone set was significantly shorter than that of the manual set (P<0.05).

CONCLUSIONS

Smartphone-aided measurement for Cobb angle showed excellent reliability and efficiency. It is suggested to popularize the use of this method in clinical practice.

摘要

研究设计

青少年特发性脊柱侧凸中智能手机辅助测量方法与手动测量方法对Cobb角的比较。

目的

评估智能手机辅助Cobb角测量方法的可靠性和测量误差,并将其可靠性和测量误差与手动测量方法进行比较。

背景数据总结

智能手机的发展为将移动技术整合到日常临床实践中提供了新机会。智能手机应用程序可为疾病的诊断和治疗提供快速辅助。Cobbmeter是一款为在苹果iPhone智能手机上测量Cobb角而设计的智能手机应用程序。目前尚无关于这种智能手机辅助测量方法的可靠性和测量误差的研究。

方法

使用53例青少年特发性脊柱侧凸伴胸椎侧凸患者的后前位X线片进行标准Cobb测量方法(手动测量)和智能手机辅助Cobb测量方法(智能手机测量)。5名脊柱外科医生分别使用手动测量方法和智能手机辅助测量方法测量Cobb角。记录每次测量所花费的时间。列出观察者内差异的频率和累积百分比分布,包括个体检查者以及所有5名检查者的总体结果。采用组内相关系数(ICC)双向混合模型的绝对一致性分析测量可靠性。方差分析计算的汇总统计数据用于提供测量误差的95%预测区间。采用配对t检验比较两组测量所花费的时间。

结果

智能手机测量组和手动测量组的观察者内和观察者间ICC均为优秀。智能手机测量组的观察者内ICC和观察者间ICC均优于手动测量组。所有测量X线片的手动测量组Cobb角平均为29.3度(范围17 - 58度),智能手机测量组为29.1度(范围18 - 56度)。智能手机测量组平均耗时13.7秒(范围8.6 - 18.5秒),而手动测量组为37.9秒(范围30.1 - 46.9秒),智能手机测量组平均耗时显著短于手动测量组(P<0.05)。

结论

智能手机辅助Cobb角测量显示出优异的可靠性和效率。建议在临床实践中推广使用该方法。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验