BACKGROUND

The superoanterior portion of the third cervical vertebra may need to be rimmed during anterior odontoid screw fixation procedures. We, therefore, retrospectively evaluated radiological data to analyze the anatomical relation between the second and third cervical vertebra of the patients who were operated by an anterior cervical approach with respect to the question if odontoid screw fixation would have been possible without rimming or not.

PATIENTS AND METHODS

Patients in whom the anterior approach for cervical disc prolapse and/or cervical stenosis was used between 2008 and 2010 were included in this study. The odontoid screw angle, and the angle between the lower second and the upper third cervical vertebral endplate were measured on intraoperative cervical lateral radiographs. If the screw line passed through the superior anterior portion of the third vertebral body, it was determined that the third cervical vertebra would have been needed to be rimmed if odontoid screwing would have been planned.

RESULTS

100 patients were included. There were 50 males and 50 females with a mean age of 47.9 years (mean ± SD: 47.9 ± 12.6 years). The mean odontoid screw angle, and the angle between the lower second and the upper third cervical vertebral endplate were 65.61° ± 3.75° and 15.24° ± 4.85° (nonparallel vertebral endplates only), respectively. The odontoid screw angle, in which the third cervical vertebra would not have been needed to be rimmed, was 63.87° ± 2.84°. In addition, the odontoid screw angle in which the third cervical vertebra would have been needed to be rimmed was 67.28° ± 3.77°.

CONCLUSION

The odontoid screw angle may be easily measured on lateral radiographs. In cases in which the odontoid screw angle is 67.28° ± 3.77° or higher, the superoanterior portion of the third cervical vertebra would be needed to be rimmed for proper screw fixation of odontoid fractures.

摘要

背景

在进行前路齿突螺钉固定手术时,可能需要对第三颈椎的上前部进行修缘。因此,我们回顾性评估了放射学数据,以分析接受颈椎前路手术患者的第二和第三颈椎之间的解剖关系,探讨是否有可能在不修缘的情况下进行齿突螺钉固定。

患者与方法

本研究纳入了2008年至2010年间因颈椎间盘突出症和/或颈椎管狭窄而采用前路手术的患者。在术中颈椎侧位X线片上测量齿突螺钉角度以及第二颈椎下终板与第三颈椎上终板之间的角度。如果螺钉线穿过第三椎体的上前部,则判定若计划进行齿突螺钉固定,则需要对第三颈椎进行修缘。

结果

共纳入100例患者。其中男性50例,女性50例,平均年龄47.9岁(平均±标准差:47.9±12.6岁)。齿突螺钉平均角度以及第二颈椎下终板与第三颈椎上终板之间的角度(仅针对终板不平行的情况)分别为65.61°±3.75°和15.24°±4.85°。无需对第三颈椎进行修缘的齿突螺钉角度为63.87°±2.84°。此外,需要对第三颈椎进行修缘的齿突螺钉角度为67.28°±3.77°。

结论

齿突螺钉角度可在侧位X线片上轻松测量。当齿突螺钉角度为67.28°±3.77°或更高时,为了对齿突骨折进行合适的螺钉固定,需要对第三颈椎的上前部进行修缘。