Baveja U K, Arya G, Goyle V, Sharma D K, Gupta M
Department of Microbiology, Maulana Azad Medical College, New Delhi.
J Commun Dis. 1990 Mar;22(1):55-9.
The diagnostic efficacy of an indirect enzyme linked immunosorbent assay (ELISA) was evaluated in cases of neurocystecercosis. Subjects studied included 22 cases and 30 controls (comprising 12 cases of surgically confirmed hydatid disease, 5 cases each of tuberculoma and P.U.O. and 8 cases of pyogenic meningitis). A standard ELISA was performed using porcine cysticerci as antigen. Sensitivity and specificity of the test were calculated for serum and cerebrospinal fluid separately. The test was found to give a sensitivity of 68 and 33 per cent for serum and C.S.F. respectively. The specificity for confirmed case was found to be cent per cent for both with the criteria of reporting used. The sensitivity of the test may be increased by using purified specific antigen and/or sandwich ELISA instead of indirect ELISA technique.
在神经囊尾蚴病病例中评估了间接酶联免疫吸附测定(ELISA)的诊断效力。研究对象包括22例患者和30名对照(包括12例经手术确诊的包虫病、各5例结核瘤和不明热以及8例化脓性脑膜炎)。使用猪囊尾蚴作为抗原进行标准ELISA。分别计算了该检测对血清和脑脊液的敏感性和特异性。结果发现该检测对血清和脑脊液的敏感性分别为68%和33%。在所采用的报告标准下,确诊病例的特异性在两者中均为100%。通过使用纯化的特异性抗原和/或夹心ELISA而非间接ELISA技术,该检测的敏感性可能会提高。