Suppr超能文献

伊朗牙医对口腔放射学安全标准的遵从情况。

Compliance of Iranian dentists with safety standards of oral radiology.

机构信息

Department of Oral and Maxillofacial Radiology, Faculty of Dentistry, Shahed University, Shahed Dental School, Tehran, Islamic Republic of Iran.

出版信息

Dentomaxillofac Radiol. 2012 Feb;41(2):159-64. doi: 10.1259/dmfr/29207955.

Abstract

OBJECTIVES

Dentists use radiographs in their daily practice. Their knowledge and behaviour towards radiographic examination can affect patients' exposure to radiation. The aim of this study was to survey the knowledge and behaviour of Iranian dentists regarding oral radiology safety standards.

METHODS

1000 questionnaires were given to the participants of the 48th Annual Congress of the Iranian Dental Association, of which 700 were returned. The participants were asked about demographic data, primary knowledge of radiation protection, selection criteria, radiographic equipment and technique, methods of patient and personnel protection and management of radiographic waste. Descriptive analysis of data was performed.

RESULTS

44% of respondents said the initial radiograph they took was of the periapical view of a limited area. 12% preferred the periapical paralleling technique. F-speed film was used by 9% and E-speed film by 62%. Only 2% had digital receptors. Proper exposure time was selected by 26.5%. The use of long and rectangular collimators was 15% and 6%, respectively. 34% occasionally covered their patients with both thyroid shields and lead aprons. 36% used the position and distance rule correctly for their own protection. Proper disposal of the used processing solutions and the lead foils were done by only 1% and 3%, respectively.

CONCLUSIONS

It can be concluded that the majority of dentists in the study group did not select the proper method, material and equipment in order to minimize the exposure of their patient to unnecessary radiation in dental radiography.

摘要

目的

牙医在日常工作中使用射线照相。他们对射线检查的知识和行为可能会影响患者接受的辐射剂量。本研究旨在调查伊朗牙医对口腔放射影像学安全标准的知识和行为。

方法

向伊朗牙科协会第 48 届年会的参与者发放了 1000 份问卷,其中 700 份被收回。参与者被问及人口统计学数据、辐射防护的基本知识、选择标准、射线照相设备和技术、患者和人员防护方法以及射线照相废物管理。对数据进行描述性分析。

结果

44%的受访者表示,他们拍摄的第一张射线照片是根尖区域的根尖片。12%的人更喜欢根尖平行技术。9%的人使用 F 速度胶片,62%的人使用 E 速度胶片。只有 2%的人有数字接收器。26.5%的人选择了适当的曝光时间。长而矩形的准直器的使用分别为 15%和 6%。34%的人偶尔会同时使用甲状腺屏蔽和铅围裙覆盖患者。36%的人正确地使用位置和距离规则来保护自己。只有 1%和 3%的人分别正确处理用过的处理液和铅箔。

结论

可以得出结论,研究组中的大多数牙医在牙科放射摄影中没有选择适当的方法、材料和设备,以尽量减少患者不必要的辐射暴露。

相似文献

3
Survey of dental radiological practice in Turkey.土耳其牙科放射学实践调查。
Dentomaxillofac Radiol. 2005 Jul;34(4):222-7. doi: 10.1259/dmfr/22885703.
8
Compliance of Michigan dentists with radiographic safety recommendations.密歇根州牙医对放射安全建议的遵守情况。
Oral Surg Oral Med Oral Pathol. 1992 Apr;73(4):510-3. doi: 10.1016/0030-4220(92)90335-n.

引用本文的文献

8

本文引用的文献

3
Dose reduction of intraoral dental radiography in Spain.西班牙口腔内牙片摄影的剂量降低
Dentomaxillofac Radiol. 2006 Jul;35(4):295-8. doi: 10.1259/dmfr/26405790.
4
Survey of dental radiological practice in Turkey.土耳其牙科放射学实践调查。
Dentomaxillofac Radiol. 2005 Jul;34(4):222-7. doi: 10.1259/dmfr/22885703.
6
Why switch to digital radiography?为何要转向数字放射成像?
J Am Dent Assoc. 2004 Oct;135(10):1437-9. doi: 10.14219/jada.archive.2004.0054.
10
Radiation dose-reduction techniques in North American dental schools.北美牙科学校的辐射剂量降低技术。
Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2002 Apr;93(4):496-505. doi: 10.1067/moe.2002.121387.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验