Suppr超能文献

儿童肿瘤病房中由污染虹吸管内的错误射流引起的铜绿假单胞菌爆发

Pseudomonas aeruginosa outbreak in a pediatric oncology care unit caused by an errant water jet into contaminated siphons.

机构信息

Pediatric Infectious Diseases, University Children's Hospital Mannheim, Heidelberg University, Mannheim, Germany.

出版信息

Pediatr Infect Dis J. 2012 Jun;31(6):648-50. doi: 10.1097/INF.0b013e31824d1a11.

Abstract

We analyzed an outbreak of invasive infections with an exotoxin U positive Pseudomonas aeruginosa strain within a pediatric oncology care unit. Environmental sampling and molecular characterization of the Pseudomonas aeruginosa strains led to identification of the outbreak source. An errant water jet into the sink within patient rooms was observed. Optimized outbreak management resulted in an abundance of further Pseudomonas aeruginosa infections within the pediatric oncology care unit.

摘要

我们分析了儿科肿瘤病房内发生的一种外毒素 U 阳性铜绿假单胞菌侵袭性感染暴发。对铜绿假单胞菌菌株进行环境采样和分子特征分析,确定了暴发源头。观察到病房内水槽上方的水射流有错误。优化暴发管理后,儿科肿瘤病房内铜绿假单胞菌感染进一步增加。