Yang Jin-Ping, Zhang Lu-Xin, Liu Tong, Liu Dai-Li, Hou Yu-Geng, Feng Hong-Tao
Tianjin Dongli District Center for Disease Control and Prevention, Tianjin, China.
Zhonghua Lao Dong Wei Sheng Zhi Ye Bing Za Zhi. 2011 Aug;29(8):629-31.
To establish a gas chromatography method for detecting the concentration of 1,1-dichloro-1-nitroethane in air of workplaces.
1,1-dichloro-1-nitroethane in air of workplaces was collected by activated charcoal tube, absorbed using carbon disulfide and analyzed by Gas Chromatography (FID) with FFAP capillary column.
The linear rang of 1,1-dichloro-1-nitroethane in this method was 4.0-858.2 microg/ml, the linear regression formula was Y = 283X-1076, the correlation coefficient was 0.9999, the lowest detection concentration was 0.4 mg/m3 (3L sampling air), the relative standard deviation (RSD) was 1.8%-4.1%, the desorption efficiency was 88.5%-90.6%, the breakthrough volume was > 0.7 mg, the sampling efficiency was 100%, the samples could be kept at ambient temperature for at least 7 days.
The indicators of this method were conformed to the requirements of "Guide for establishing occupational health standards--Determination methods of air chemicals in workplace". This method could be used to detect 1,1-dichloro-1-nitroethane in air of workplaces.