手动探诊深度的内-间检查者可重复性。

Intra- and inter-examiner reproducibility of manual probing depth.

出版信息

Braz Oral Res. 2012 Jan-Feb;26(1):57-63. doi: 10.1590/s1806-83242012000100010.

Abstract

The periodontal probe remains the best clinical diagnostic tool for the collection of information regarding the health status and the attachment level of periodontal tissues. The aim of this study was to evaluate intra- and inter-examiner reproducibility of probing depth (PD) measurements made with a manual probe. With the approval of an Ethics Committee, 20 individuals without periodontal disease were selected if they presented at least 6 teeth per quadrant. Using a Williams periodontal probe, three calibrated thesis-level students (k > 0.6) assessed PD at 6 sites per tooth, from the gingival margin to the bottom of the periodontal sulcus (rounded to the next 0.5 mm). Initial and repeated measurements were performed by the same three examiners. The intra-examiner agreement (± 1 mm > 90%) was 99.85%, 100%, and 100% for the three examiners, respectively. When the variables vestibular/lingual surfaces, mesial/distal surfaces, or superior/inferior jaws were evaluated, no significant differences in reproducibility were detected at the inter-examiner level (p < 0.05). At this level, the only significant differences observed were in the three examiners' measurements of the anterior and posterior sites. While high intra-examiner reproducibility was detected, inter-examiner level proved to be low. We can conclude that measurement of PD with a manual periodontal probe produced high reproducibility in healthy individuals. The operators position can affect the reproducibility of repeated measures of PD. Calibration and operator training, rather than operator experience, were fundamental for reproducibility. Other factors, such as individual technique and probing depth force, can affect inter-examiner reproducibility.

摘要

牙周探针仍然是收集牙周组织健康状况和附着水平信息的最佳临床诊断工具。本研究旨在评估手动探针探测深度(PD)测量的内-间检查者重复性。在伦理委员会的批准下,如果每个象限至少有 6 颗牙齿,选择没有牙周病的 20 个人。使用 Williams 牙周探针,三名经过校准的硕士水平学生(k > 0.6)对每个牙齿的 6 个位点进行 PD 评估,从牙龈边缘到牙周袋底部(四舍五入到下一个 0.5 毫米)。初始和重复测量由同三名检查者进行。三位检查者的内检查者一致性(± 1 毫米> 90%)分别为 99.85%、100%和 100%。当评估颊/舌面、近/远中面或上/下颌时,在间检查者水平上未发现重复性的显着差异(p < 0.05)。在这个水平上,唯一观察到的显着差异是三位检查者对前牙和后牙的测量。虽然检测到了高度的内检查者可重复性,但间检查者水平的可重复性较低。我们可以得出结论,使用手动牙周探针测量 PD 在健康个体中具有较高的可重复性。操作员的位置会影响 PD 重复测量的可重复性。校准和操作员培训,而不是操作员经验,是可重复性的基础。其他因素,如个体技术和探测深度力,会影响间检查者的可重复性。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验