Gebuhr P H, Olsen I J, Sonne-Holm S
Ortopaedkirurgisk afdeling, Hvidovre Hospital, København.
Ugeskr Laeger. 1990 Nov 12;152(46):3458-60.
The Swanson silastic implant was employed in 16 wrists in 13 patients who were followed up for a median of 59 months. At follow up examination, pain had decreased in ten wrists while three remained unchanged. Ten patients were satisfied with the total result. Only few complications occurred. Prosthetic fracture occurred in two wrists (14%). The authors consider that the Swanson silastic wrists implant can produce favourable results in patients with rheumatoid arthritis with moderate to severe radiological destruction.
13名患者的16个腕关节采用了斯旺森硅橡胶植入物,中位随访时间为59个月。随访检查时,10个腕关节疼痛减轻,3个无变化。10名患者对总体结果满意。仅发生了少数并发症。2个腕关节发生假体骨折(14%)。作者认为,斯旺森硅橡胶腕关节植入物可使类风湿关节炎伴中度至重度放射学破坏的患者获得良好疗效。