Department of Ophthalmology, Military Institute of Medicine, 128 Szaserów Str. 04-141 Warsaw 44, Poland.
Br J Ophthalmol. 2012 May;96(5):624-8. doi: 10.1136/bjophthalmol-2011-300945. Epub 2012 Mar 7.
To define parameters of autonomic nervous system activity in patients with normal tension glaucoma (NTG).
Ambulatory 24-h ECG (Lifecard CF) and 24-h blood pressure (BP) monitoring (SpaceLab 90207-30) were carried out in 54 patients with NTG (44 women, mean age 59.7) and 43 matched control subjects (34 women, mean age 57.0). Heart rate variability time and frequency domain parameters (low frequency (LF), high frequency (HF) and LF/HF ratio), BP variability (BPV), diurnal and nocturnal BP variables were compared between study groups.
Patients with NTG demonstrated higher LF, LF/HF and lower HF values than control subjects for the 24-h, daytime and night-time periods. The mean 24-h, daytime and night-time LF/HF ratios were statistically higher in patients with glaucoma as compared to control subjects ((3.2±1.5 vs 2.2±0.8, p=0.0009), (3.5±1.7 vs 2.7±1.0, p=0.0173) and (2.6±1.7 vs 1.4±0.6, p=0.0001), respectively). There were no statistical differences in the mean BP during the whole day, daytime and night-time, and in BPV (10.4±1.9 vs 10.5±2.1, p=0.790) between study groups. No difference was also found in the percentage decrease in night-time mean BP (12.3% vs 13.6%, p=0.720). 'Dippers', 'non-dippers' and 'overdippers' with NTG showed significantly higher LF/HF ratio as compared to the same subgroups of control subjects.
The sympathovagal balance of autonomic nervous system in patients with NTG shifted towards sympathetic activity however with no change of 24-h pattern of BPV as compared to controls.
定义正常眼压性青光眼(NTG)患者自主神经系统活动的参数。
对 54 例 NTG 患者(44 名女性,平均年龄 59.7 岁)和 43 名匹配的对照组(34 名女性,平均年龄 57.0 岁)进行了动态 24 小时心电图(Lifecard CF)和 24 小时血压(BP)监测(SpaceLab 90207-30)。比较了两组间心率变异性时域和频域参数(低频(LF)、高频(HF)和 LF/HF 比值)、BP 变异性(BPV)、昼夜 BP 变量。
与对照组相比,NTG 患者的 24 小时、白天和夜间的 LF、LF/HF 比值更高,HF 比值更低。与对照组相比,青光眼患者的平均 24 小时、白天和夜间 LF/HF 比值均显著升高((3.2±1.5 比 2.2±0.8,p=0.0009),(3.5±1.7 比 2.7±1.0,p=0.0173)和(2.6±1.7 比 1.4±0.6,p=0.0001))。两组在全天、白天和夜间的平均 BP 以及 BPV 方面无统计学差异(10.4±1.9 比 10.5±2.1,p=0.790)。两组夜间平均 BP 下降百分比也无差异(12.3%比 13.6%,p=0.720)。与对照组相同亚组相比,NTG 的“杓型”、“非杓型”和“超杓型”患者的 LF/HF 比值显著升高。
与对照组相比,NTG 患者自主神经系统的交感-副交感平衡向交感活动转移,但 24 小时 BPV 模式无变化。