BACKGROUND

The performance of the Capilia test for rapid identification of Mycobacterium tuberculosis complex (MTC) in Mycobacterium Growth Indicator Tube (MGIT) positive samples with contaminating organisms is not well documented.

OBJECTIVE

To assess the diagnostic yield of the Capilia test in the rapid identification of MTC in MGIT-positive cultures.

DESIGN

A total of 459 selected sputum samples were cultured using BACTEC™ MGIT™ 960. Tubes flagged positive by the MGIT instrument (MGIT-positive) were examined for acid-fast bacilli and cording in smears, spotted on blood agar (BA), subcultured for biochemical tests and tested using the Capilia test. Based on smear and growth on BA, MGIT-positive tubes were grouped into MGIT true-positive, MGIT-positive with contamination and MGIT contamination. Performance parameters of Capilia test such as sensitivity, specificity, efficiency, and positive and negative predictive values (PPV, NPV) for each of these groups were determined against biochemical tests as gold standard.

RESULTS

Of the 346 MGIT-positives, respectively 233, 73 and 40 were MGIT true-positive, MGIT-positive with contamination and MGIT contamination. For the three groups, the PPV and NPV of the Capilia test were respectively 97%, 96% and 100%, and 32%, 27% and 60%.

CONCLUSION

In settings with high contamination of MGIT cultures, the performance of the Capilia test is diminished.

摘要

背景

Capilia 测试在快速鉴定分枝杆菌生长指示管(MGIT)阳性样本中分枝杆菌复合群(MTC)的性能尚未得到充分记录,这些样本中存在污染菌。

目的

评估 Capilia 测试在快速鉴定 MGIT 阳性培养物中 MTC 的诊断效果。

设计

共选择了 459 份痰液样本,使用 BACTEC™ MGIT™ 960 进行培养。MGIT 仪器标记为阳性的管(MGIT 阳性)通过抗酸杆菌染色和涂片中的条索状结构检查,在血琼脂(BA)上点样,进行生化试验的亚培养,并使用 Capilia 测试进行检测。根据涂片和 BA 上的生长情况,将 MGIT 阳性管分为 MGIT 真正阳性、MGIT 阳性伴污染和 MGIT 污染。Capilia 测试的性能参数(如敏感性、特异性、效率以及对每组的阳性和阴性预测值(PPV、NPV))针对生化测试作为金标准进行确定。

结果

在 346 个 MGIT 阳性中,分别有 233、73 和 40 个为 MGIT 真正阳性、MGIT 阳性伴污染和 MGIT 污染。对于这三组,Capilia 测试的 PPV 和 NPV 分别为 97%、96%和 100%,32%、27%和 60%。

结论

在 MGIT 培养物污染程度较高的情况下,Capilia 测试的性能会降低。