Suppr超能文献

使用定义抗原底物球(DASS)进行缀合物活性定量和视觉评估时激活和封闭程序的比较。

Comparison of activation and blocking procedures in the use of defined antigen substrate spheres (DASS) for quantitative and visual assessment of conjugate activity.

作者信息

Raybould T J, Chantler S

出版信息

J Immunol Methods. 1979;27(4):309-18. doi: 10.1016/0022-1759(79)90208-4.

Abstract

The use of Sepharose beads in the defined antigen substrate sphere (DASS) immunofluorescent system has been restricted by the need for sophisticated equipment for fluorescence quantitation since reliable subjective reading is not possible. This paper describes a method for visual assessment of results in this system. Antigen is coupled to sodium metaperiodate activated. Cross-linked Sepharose 4B beads and blocked with rhodamine-BSA prior to reduction. This procedure eliminates the use of the hazardous cyanogen bromide activation process and is potentially suitable for use in both direct systems for evaluation of specificity and potency of fluorescent conjugates and in indirect systems for serological screening of sera for specific antibody.

摘要

由于无法进行可靠的主观读数,在限定抗原底物球(DASS)免疫荧光系统中使用琼脂糖珠受到荧光定量所需精密设备的限制。本文描述了一种在此系统中对结果进行视觉评估的方法。抗原与经偏高碘酸钠活化的交联琼脂糖4B珠偶联,并在还原前用罗丹明-牛血清白蛋白封闭。此程序省去了危险的溴化氰活化过程,并且可能适用于评估荧光偶联物特异性和效价的直接系统以及用于血清中特异性抗体血清学筛查的间接系统。