通风实验室中的前开式安全柜。

Open fronted safety cabinets in ventilated laboratories.

作者信息

Clark R P, Osborne R W, Pressey D C, Grover F, Keddie J R, Thomas C

机构信息

Thermal Biology Group, Clinical Research Centre, Harrow, UK.

出版信息

J Appl Bacteriol. 1990 Sep;69(3):338-58. doi: 10.1111/j.1365-2672.1990.tb01525.x.

Abstract

Open fronted Class I and II microbiological safety cabinets (MSCs) are required by the British Standard 5726 to provide similar levels of operator protection (viz. 10(5). In laboratories that are naturally ventilated large numbers of both types of cabinets have been shown to exceed this requirement consistently over a number of years. The designs of some mechanically ventilated laboratories, however, produce excessive turbulence and draughts that can prejudice containment at the front aperture. On-site commissioning tests to determine operator protection factor are now well established and are recognized as being essential to the setting up of all open fronted cabinets in both ventilated and unventilated laboratories. This paper shows that where environmental conditions induce unsatisfactory cabinet containment, adjustments to air supply and exhaust systems can be made which will enable both Class I and II cabinets to produce operator protection factors in excess of 10(5). When compatibility is achieved between the local environment and the cabinets it is demonstrated that disturbances at the front aperture, caused by operator working procedures or by disturbances due to personnel movement within the room, have similar effects on both Class I and II cabinets. Once performance levels have been satisfactorily achieved, regular containment testing has shown that consistent performance can be maintained. These aspects of open fronted safety cabinet performance are discussed in relation to ventilated laboratories suitable for work with the human immunodeficiency virus (HIV). Of paramount importance in the future is the necessity to design laboratory air systems that will be compatible with satisfactory safety cabinet performance--a relatively new requirement in ventilation system specifications.

摘要

英国标准5726要求,I级和II级前开口式微生物安全柜(MSC)应提供相似水平的操作人员防护(即10⁵)。在自然通风的实验室中,多年来大量的这两种类型的安全柜均已被证明始终能超过这一要求。然而,一些机械通风实验室的设计会产生过多的紊流和气流,这可能会影响前开口处的防护效果。现在,确定操作人员防护系数的现场调试测试已得到充分确立,并被认为对于在通风和非通风实验室中安装所有前开口式安全柜至关重要。本文表明,在环境条件导致安全柜防护效果不理想的情况下,可以对送风系统和排风系统进行调整,这将使I级和II级安全柜均能产生超过10⁵的操作人员防护系数。当局部环境与安全柜之间实现兼容性时,可以证明,由操作人员的工作程序或室内人员活动引起的前开口处的干扰,对I级和II级安全柜具有相似的影响。一旦性能水平达到令人满意的程度,定期的防护测试表明可以维持稳定的性能。本文结合适用于人类免疫缺陷病毒(HIV)相关工作的通风实验室,讨论了前开口式安全柜性能的这些方面。未来至关重要的是,必须设计出与安全柜的良好性能相兼容的实验室空气系统,这在通风系统规范中是一个相对较新的要求。

相似文献

1
Open fronted safety cabinets in ventilated laboratories.
J Appl Bacteriol. 1990 Sep;69(3):338-58. doi: 10.1111/j.1365-2672.1990.tb01525.x.
2
Continued successful operation of open-fronted microbiological safety cabinets in a force-ventilated laboratory.
J Appl Bacteriol. 1991 Nov;71(5):434-8. doi: 10.1111/j.1365-2672.1991.tb03813.x.
5
Performance of exhaust-protective (class I) biological 'safety' cabinets.
J Clin Pathol. 1979 Jun;32(6):576-83. doi: 10.1136/jcp.32.6.576.
6
Fluid dynamics of cytotoxic safety cabinets.
Ann Occup Hyg. 2010 Mar;54(2):236-46. doi: 10.1093/annhyg/mep087. Epub 2009 Dec 9.
7
The effect of microbiological containment systems on dexterity.
J Occup Environ Hyg. 2007 Mar;4(3):166-73. doi: 10.1080/15459620601163172.
10
A comparison of methods to measure operator protection factors in open-fronted microbiological safety cabinets.
J Appl Bacteriol. 1981 Dec;51(3):461-73. doi: 10.1111/j.1365-2672.1981.tb01265.x.

引用本文的文献

1
Validation of cross-contamination control in biological safety cabinet for biotech/pharmaceutical manufacturing process.
Environ Sci Pollut Res Int. 2015 Dec;22(23):19264-72. doi: 10.1007/s11356-015-5091-5. Epub 2015 Aug 11.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验