The Italian recommendation NORMAL 13/83, later replaced by the UNI 11087/2003 norm, were used as standard for soluble salts extraction from construction materials. These standards are based on long-time stirring (72 and 2h, respectively) of the sample in deionized water. In this work two ultrasound based methods were optimized in order to reduce the extraction time while efficiency is improved. The instrumental variables involved in the extraction assisted by ultrasound bath and focused ultrasounds were optimized by experimental design. As long as it was possible, the same non-instrumental parameters values as those of standard methods were used in order to compare the results obtained on a mortar sample showing a black crust by the standards and the optimized methods. The optimal extraction time for the ultrasounds bath was found to be of two hours. Although the extraction time was equal to the standard UNI 11087/2003, the obtained extraction recovery was improved up to 119%. The focused ultrasound system achieved also better recoveries (up to 106%) depending on the analyte in 1h treatment time. The repeatabilities of the proposed ultrasound based methods were comparables to those of the standards. Therefore, the selection of one or the other of the ultrasound based methods will depend on topics such as laboratory facilities or number of samples, and not in aspects related with their quality parameters.

摘要

意大利推荐标准 NORMAL 13/83 后被 UNI 11087/2003 标准取代,被用于从建筑材料中提取可溶性盐。这些标准基于对样品在去离子水中长时间搅拌(分别为 72 小时和 2 小时)。在这项工作中,为了提高效率同时缩短提取时间,对两种基于超声的方法进行了优化。通过实验设计优化了超声浴和聚焦超声辅助提取中涉及的仪器变量。只要有可能,就使用与标准方法相同的非仪器参数值来比较标准和优化方法对显示出标准黑壳的灰浆样品的结果。发现超声浴的最佳提取时间为两小时。尽管提取时间与标准 UNI 11087/2003 相同,但提取回收率提高了 119%。在 1 小时处理时间内,聚焦超声系统还实现了更好的回收率(高达 106%),具体取决于分析物。所提出的基于超声的方法的重复性与标准方法相当。因此,选择基于超声的方法之一或另一种方法将取决于实验室设施或样品数量等因素,而不是与其质量参数相关的因素。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验