[静脉肾盂造影期间无症状血压和脉搏率变化。离子型对比剂与非离子型对比剂]

[Asymptomatic blood pressure and pulse rate changes during intravenous urography. Ionic contrast media vs. nonionic contrast media].

作者信息

Miwa K

机构信息

Department of Radiology School of Medicine, Showa University.

出版信息

Nihon Igaku Hoshasen Gakkai Zasshi. 1990 Sep 25;50(9):1082-6.

PMID:2247349
Abstract

In 8,232 examinations of intravenous urography (4,832 examinations with ionic contrast media and 3,400 examinations with nonionic contrast media), systemic blood pressure and pulse rate were continuously monitored by an automatic blood pressure and pulse rate monitoring device before and after injection of contrast media. The intravenous injection of ionic contrast media caused mild to moderate hypotensive reactions (20%-39% decrease of systemic blood pressure) in 7 examinations (0.14%) and severe hypotensive reactions (greater than 40% decrease of systemic blood pressure) in 12 examinations (0.25%). There were no clinical symptoms other than hypotensive reactions in 8 of the 19 examinations (42.1%). On the other hand, the intravenous injection of nonionic contrast media did not cause severe hypotensive reactions but mild hypotensive reactions (20%-29% decrease of systemic blood pressure) in 3 examinations (0.09%). These 3 examinations did not have clinical symptoms other than hypotensive reactions. Of the 19 examinations using ionic contrast media, the hypotensive reactions with significant change of pulse rate (greater than 20%) was associated with increase of pulse rate in 17 examinations and decrease of pulse rate in 2 examinations. On the other hand, the hypotensive reactions had an association with a significant increase (greater than 20%) of the pulse rate in only one of the 3 examinations using nonionic contrast media. The pulse rate was unchanged after injection of contrast media in the remaining 2 examinations although there was mild hypotension. In conclusion, nonionic contrast media caused fewer and less severe changes in blood pressure and pulse rate without obvious clinical symptoms compared with ionic contrast media.

摘要

在8232例静脉肾盂造影检查中(4832例使用离子型造影剂,3400例使用非离子型造影剂),在注射造影剂前后,通过自动血压和脉搏率监测装置持续监测全身血压和脉搏率。静脉注射离子型造影剂在7例检查中(0.14%)引起轻度至中度低血压反应(全身血压下降20%-39%),在12例检查中(0.25%)引起严重低血压反应(全身血压下降超过40%)。19例检查中有8例(42.1%)除低血压反应外无其他临床症状。另一方面,静脉注射非离子型造影剂未引起严重低血压反应,但在3例检查中(0.09%)引起轻度低血压反应(全身血压下降20%-29%)。这3例检查除低血压反应外无其他临床症状。在19例使用离子型造影剂的检查中,脉搏率有显著变化(超过20%)的低血压反应,17例与脉搏率增加有关,2例与脉搏率下降有关。另一方面,在3例使用非离子型造影剂的检查中,只有1例低血压反应与脉搏率显著增加(超过20%)有关。其余2例检查注射造影剂后脉搏率未变,尽管有轻度低血压。总之,与离子型造影剂相比,非离子型造影剂引起的血压和脉搏率变化较少且较轻,无明显临床症状。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验