Abstract

The contribution of cataract to the decrease of visual field in patients with glaucoma is difficult to ascertain. To attempt to quantitate the change in visual field due to cataract, we examined 27 eyes of 26 patients before and after cataract extraction. The examination consisted of measurement of best refraction with visual acuity, visual field testing with the pupil dilated, measurement of lens opacity, determination of the intraocular pressure, and evaluation of the character of the cataract before surgery and of the posterior capsule after surgery. The results reaffirmed the detrimental effect that cataract may have on the visual field but also showed that the heterogeneity of cataracts limits the usefulness of the lens opacity meter in quantitating the extent of visual field loss due to cataract.

摘要

白内障对青光眼患者视野缺损的影响难以确定。为了试图量化白内障导致的视野变化,我们对26例患者的27只眼在白内障摘除术前和术后进行了检查。检查包括测量最佳矫正视力、散瞳后进行视野测试、测量晶状体混浊度、测定眼压,以及评估手术前白内障的特征和手术后后囊膜的情况。结果再次证实了白内障可能对视野产生的有害影响,但也表明白内障的异质性限制了晶状体混浊度计在量化白内障所致视野缺损程度方面的作用。