Department of Restorative Dentistry, Araraquara Dental School, UNESP-Univ Estadual Paulista, Araraquara, SP, Brazil.
Microsc Res Tech. 2012 Sep;75(9):1229-32. doi: 10.1002/jemt.22053. Epub 2012 Apr 12.
The aim of this study was to compare the percentage of gutta-percha (PGP) in mesial root canals of mandibular molars obturated with LC (Lateral Compaction) or SC (Single Cone) ProTaper Universal System techniques at different levels of the root. Mesial root canals of 20 human permanent molars with similar anatomical characteristics were instrumented using the ProTaper Universal rotary system technique until the F2 instrument, with 20 canals filled by SC ProTaper Universal technique and 20 canals by the LC technique. The mesial roots were sectioned transversely to 3, 5, and 7 mm from the root apex. Digital images of specimens were obtained at MIC-D digital microscope in increases of 30 to 35X. The gutta-percha area was measured using ImageTool software. Data were analyzed using two-way ANOVA and Bonferroni test (α = 0.05). The SC technique provided greater PGP than the LC technique in the apical third (3 mm) (P < 0.001). In the other thirds (5 and 7 mm) there was no statistical difference between the two techniques regarding the PGP (P > 0.05). There was no statistically significant difference between thirds of the root canal for both techniques (P > 0.05). It was concluded that SC technique provided greater PGP than the LC technique in the apical third of mesial root canals of mandibular molars. There was no difference between the two techniques regarding the PGP in the cervical and middle thirds.
本研究旨在比较使用 LC(侧向压实)或 SC(单根锥)ProTaper 通用系统技术在根尖不同水平对下颌磨牙近中根管进行塑化时的塑化剂(PGP)百分比。使用 ProTaper 通用旋转系统技术对 20 个人类恒磨牙具有相似解剖特征的近中根管进行根管预备,直到 F2 器械,其中 20 个根管用 SC ProTaper 通用技术填充,20 个根管用 LC 技术填充。近中根从根尖到 3、5 和 7mm 处横向切割。在 MIC-D 数字显微镜下以 30 到 35X 的倍数获得标本的数字图像。使用 ImageTool 软件测量塑化剂面积。使用双向方差分析和 Bonferroni 检验(α=0.05)对数据进行分析。SC 技术在根尖三分之一(3mm)处提供的 PGP 高于 LC 技术(P<0.001)。在其他三分之一(5 和 7mm)处,两种技术之间的 PGP 没有统计学差异(P>0.05)。两种技术的根管三分之一之间没有统计学上的显著差异(P>0.05)。结论:SC 技术在下颌磨牙近中根管根尖三分之一处提供的 PGP 高于 LC 技术。两种技术在颈中和中三分之一处的 PGP 没有差异。