消毒剂对印模材料和石膏模型尺寸精度及表面质量的影响。

The effects of disinfectants on dimensional accuracy and surface quality of impression materials and gypsum casts.

作者信息

Amin Wala M, Al-Ali Muna H, Al Tarawneh Sandra K, Taha Sahar Th, Saleh Mohamed W, Ereifij Nadia

机构信息

Department of Prosthetic Dentistry, Faculty of Dentistry, University of Jordan, P.O. Box 13455, Amman 11942, Jordan.

出版信息

J Clin Med Res. 2009 Jun;1(2):81-9. doi: 10.4021/jocmr2009.04.1235. Epub 2009 Jun 21.

Abstract

BACKGROUND

The study aimed to evaluating the effect of disinfecting impression materials on the dimensional accuracy and surface quality of the resulting casts.

METHODS

Impressions of a steel die constructed according to ANSI/ADA specification No.18 were made with each of alginate, addition cured silicone, condensation cured silicone and zinc oxide eugenol paste, and disinfected consequently by each of 0.2% chlorhexidine gluconate, 1% sodium hypochlorite, 2% gluteraldehyde for 5 minutes, and 0.5% sodium hypochlorite for 10 minutes. Dimensions of the disinfected impressions and their resultant casts were measured using a computerized digital caliper, and the dimensional changes were calculated. Reproduction of detail and surface quality of the resultant casts were assessed by grading casts surfaces according to a specific scoring system.

RESULTS

The 0.5% sodium hypochlorite was found to produce the least dimensional changes in all the impression materials. Corsodyl produced the maximum changes in both alginate and zinc-oxide eugenol while addition-cured silicon was most affected by Gluteraldehyde and condensation-cured silicon was most affected by Hexana. The dimensional changes, however, were minimal and clinically insignificant. Addition-cured silicon showed the best surface quality and dimensional stability followed by condensation-cured silicon. Alginate and zinc-oxide eugenol had poorer surface quality and were affected to a higher extent by the disinfection procedures.

CONCLUSIONS

The results were comparable with the standard specifications for dimensional stability. Recommendations were made for the use of 10 minutes immersion in 0.5% sodium hypochlorite as the most appropriate disinfection protocol to the investigated impression materials.

KEYWORDS

Disinfectants; Gypsum casts; Impressions; Alginate; Addition-cured silicone; Sodium hypochlorite.

摘要

背景

本研究旨在评估对印模材料进行消毒处理对所得模型的尺寸精度和表面质量的影响。

方法

按照美国国家标准学会/美国牙医学会(ANSI/ADA)第18号规范制作钢模的印模,分别使用藻酸盐、加成型硅橡胶、缩合型硅橡胶和氧化锌丁香酚糊剂制取印模,随后分别用0.2%葡萄糖酸氯己定、1%次氯酸钠、2%戊二醛浸泡5分钟以及0.5%次氯酸钠浸泡10分钟进行消毒。使用计算机化数字卡尺测量消毒后印模及其所得模型的尺寸,并计算尺寸变化。根据特定评分系统对所得模型的表面细节再现情况和表面质量进行评估分级。

结果

发现0.5%次氯酸钠在所有印模材料中产生的尺寸变化最小。洗必泰在藻酸盐和氧化锌丁香酚印模材料中产生的变化最大,而加成型硅橡胶受戊二醛影响最大,缩合型硅橡胶受己二胺影响最大。然而,这些尺寸变化极小,在临床上无显著意义。加成型硅橡胶表现出最佳的表面质量和尺寸稳定性,其次是缩合型硅橡胶。藻酸盐和氧化锌丁香酚的表面质量较差,且受消毒程序的影响程度更高。

结论

结果与尺寸稳定性的标准规范相当。建议将在0.5%次氯酸钠中浸泡10分钟作为对所研究印模材料最合适的消毒方案。

关键词

消毒剂;石膏模型;印模;藻酸盐;加成型硅橡胶;次氯酸钠