鸡眼中超声检查与光学低相干干涉测量法的比较

Ultrasonography and optical low-coherence interferometry compared in the chicken eye.

作者信息

Penha Alexandra Marcha, Burkhardt Eva, Schaeffel Frank, Feldkaemper Marita P

机构信息

Institute for Ophthalmic Research, Section of Neurobiology of the Eye, University Eye Hospital, Tuebingen, Germany.

出版信息

Optom Vis Sci. 2012 Jun;89(6):916-21. doi: 10.1097/OPX.0b013e318257a255.

Abstract

PURPOSE

To compare ocular biometry [anterior chamber depth (ACD), lens thickness (LT), vitreous chamber depth (VCD), and axial length (AL)] using A-scan ultrasonography and optical low-coherence interferometry (OLCI) in the chicken eye.

METHODS

Two-week-old chicks (n = 42) were measured. Bland-Altman plots and repeatability and correlation analyses were calculated for both methods.

RESULTS

There was a high correlation between both methods for ACD (r = 0.6144, p < 0.0001), VCD (r = 0.9595, p < 0.0001), and AL (r = 0.9290, p < 0.0001) but not for LT (r = 0.1604, p = 0.144). Measurements by OLCI were more consistent (smaller coefficients of variation and higher intraclass correlation). Bland-Altman plots showed that ultrasound provided larger values for LT, VCD, and AL but not for ACD [differences between ultrasound and OLCI (mean ± SD): ACD = -0.11 ± 0.12 mm; LT = 0.10 ± 0.09 mm; VCD = 0.25 ± 0.08 mm; AL = 0.50 ± 0.16 mm].

CONCLUSIONS

A high correlation between both techniques was found for three of the four parameters (ACD, VCD, and AL). However, as the absolute values were different, both techniques cannot replace each other mainly because (1) one is non-contact and the other contact and can induce a minor indentation of the cornea and (2) each device uses different types of waves that cross the ocular interfaces differently. While consistency and repeatability were better by OLCI, a disadvantage is that, different from humans, it can only be used in anesthetized chicks.

摘要

目的

使用A超超声检查和光学低相干干涉测量法(OLCI)比较鸡眼中的眼生物测量参数[前房深度(ACD)、晶状体厚度(LT)、玻璃体腔深度(VCD)和眼轴长度(AL)]。

方法

对两周龄雏鸡(n = 42)进行测量。计算两种方法的Bland-Altman图、重复性和相关性分析。

结果

两种方法在ACD(r = 0.6144,p < 0.0001)、VCD(r = 0.9595,p < 0.0001)和AL(r = 0.9290,p < 0.0001)方面具有高度相关性,但在LT方面无相关性(r = 0.1604,p = 0.144)。OLCI测量结果更具一致性(变异系数更小,组内相关系数更高)。Bland-Altman图显示,超声测量的LT、VCD和AL值更大,但ACD值并非如此[超声与OLCI之间的差异(均值±标准差):ACD = -0.11±0.12 mm;LT = 0.10±0.09 mm;VCD = 0.25±0.08 mm;AL = 0.50±0.16 mm]。

结论

在四个参数中的三个(ACD、VCD和AL)上,两种技术之间存在高度相关性。然而,由于绝对值不同,两种技术不能相互替代,主要原因是(1)一种是非接触式的,另一种是接触式的,可能会导致角膜轻微压痕;(2)每种设备使用不同类型的波,它们穿过眼界面的方式不同。虽然OLCI的一致性和重复性更好,但缺点是,与人类不同,它只能用于麻醉后的雏鸡。