Antibiotic-loaded bone cement is widely used to treat musculoskeletal infections. Here we tested whether the curing temperature affected pore size of the cement and antibiotic release. Bone cement containing vancomycin was cured at 3 temperatures (50, 25 and 0°C). The solidified vancomycin-loaded cement was stored for 1-week at 25 and 5°C and then assayed for antibiotic release. We found that a significantly higher proportion of vancomycin was released from cement cured at 0°C versus that cured at 50°C, and that lower storage temperature also increased antibiotic release.
载抗生素骨水泥被广泛用于治疗肌肉骨骼感染。在此,我们测试了固化温度是否会影响骨水泥的孔径和抗生素释放。含万古霉素的骨水泥在3个温度(50、25和0°C)下固化。将固化后的载万古霉素骨水泥在25和5°C下储存1周,然后检测抗生素释放情况。我们发现,与在50°C固化的骨水泥相比,在0°C固化的骨水泥释放出的万古霉素比例显著更高,而且较低的储存温度也会增加抗生素释放。