乳腺影像报告和数据系统(BI-RADS)乳腺X线摄影术语词典的观察者变异性。

Observer Variability of the Breast Imaging Reporting and Data System (BI-RADS) Lexicon for Mammography.

作者信息

Adibelli Zehra H, Ergenc Ruken, Oztekin Ozgur, Ecevit Suheyla, Unal Gokhan, Abal Yusuf

机构信息

Radiology Department, Izmir Bozyaka Training and Research Hospital, Turkey.

出版信息

Breast Care (Basel). 2010 Mar;5(1):11-16. doi: 10.1159/000272277. Epub 2010 Feb 16.

Abstract

AIM

We aimed to determine the inter- and intra-observer variabilities between breast radiologists and a general radiologist in categorizing mammographic lesions using the Breast Imaging Reporting and Data System (BI-RADS), and to evaluate the effects of the histopathologic results on the variability. METHODS: Mammograms from 142 women who underwent biopsy were evaluated. 3 breast radiologists (2 with >10 years experience and 1 with 1 year experience) and 1 general radiologist retrospectively reviewed mammograms twice within an 8-week interval. Inter- and intra-observer variabilities were assessed with Cohen's kappa statistic, and the positive predictive value for final assessments was calculated. RESULTS: The intra-observer variability for mass and calcification assessments was moderate to almost perfect (kappa values: 0.41-1) for breast imagers and was fair to substantial for the general radiologist (kappa values: 0.21-0.8). Inter-observer agreement between the breast imagers was higher than between the breast and general radiologists. There was no apparent difference in agreement between observers for malignant and benign subgroups. CONCLUSIONS: The differences in intra- and inter-observer agreement between the breast imagers and the general radiologist affirm the utility of the BI-RADS lexicon. The histopathologic results of the lesions do not affect the agreement. BI-RADS is a simple and adequate tool for assessing mammograms, even after only 1 year of training.

摘要

目的

我们旨在确定乳腺放射科医生和一名普通放射科医生在使用乳腺影像报告和数据系统(BI-RADS)对乳腺钼靶病变进行分类时的观察者间和观察者内变异性,并评估组织病理学结果对变异性的影响。方法:对142名接受活检的女性的乳腺钼靶片进行评估。3名乳腺放射科医生(2名有超过10年经验,1名有1年经验)和1名普通放射科医生在8周的间隔内对乳腺钼靶片进行了两次回顾性评估。用Cohen's kappa统计量评估观察者间和观察者内变异性,并计算最终评估的阳性预测值。结果:乳腺影像医生对肿块和钙化评估的观察者内变异性为中度至几乎完美(kappa值:0.41 - 1),普通放射科医生的观察者内变异性为一般至较高(kappa值:0.21 - 0.8)。乳腺影像医生之间观察者间的一致性高于乳腺影像医生与普通放射科医生之间的一致性。观察者对恶性和良性亚组的一致性没有明显差异。结论:乳腺影像医生和普通放射科医生在观察者内和观察者间一致性上的差异证实了BI-RADS词汇表的实用性。病变的组织病理学结果不影响一致性。即使仅经过1年的培训,BI-RADS也是评估乳腺钼靶片的一种简单且充分的工具。

相似文献

本文引用的文献

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验