Suppr超能文献

乳腺影像报告和数据系统标准化乳腺X线摄影术语词典:病变描述中的观察者变异性

Breast imaging reporting and data system standardized mammography lexicon: observer variability in lesion description.

作者信息

Baker J A, Kornguth P J, Floyd C E

机构信息

Department of Radiology, Duke University Medical Center, Durham, NC 27710, USA.

出版信息

AJR Am J Roentgenol. 1996 Apr;166(4):773-8. doi: 10.2214/ajr.166.4.8610547.

Abstract

OBJECTIVE

The American College of Radiology has recommended the Breast Imaging Reporting and Data System (BI-RADS) as a standardized scheme for describing mammographic lesions. The objective of this study was to measure inter- and intraobserver variabilities of radiologists' descriptions of mammographic lesions with the BI-RADS standardized lexicon.

MATERIALS AND METHODS

Sixty mammographic studies with abnormal findings were independently evaluated by five radiologists. Readers described each lesion by selecting a single term from the BI-RADS lexicon for each of eight morphologic categories: calcification distribution, number, and description; mass margin, shape, and density; associated findings; and special cases. Additionally, each reader assessed the significance of each lesion on a five-point scale. One observer read each case twice. Inter- and intraobserver variabilities for each description and interpretation category of the BI-RADS lexicon were determined with Cohen's kappa statistic. Radiologists' specific use of calcification descriptors was evaluated in detail.

RESULTS

Substantial agreement was observed between readers for choosing terms to describe masses and calcifications (kappa value range, 0.50 +/- 0.02-0.77 +/- 0.03). Intraobserver agreement for these categories was similar (kappa value range, 0.57 +/- 0.07-0.84 +/- 0.09). Considerable inter- and intraobserver variabilities were noted for the "associated findings" and "special cases" categories (kappa value range, -0.02 +/- 0.14-0.38 +/- 0.12), a result that in part reflected the small number of cases to which these categories were assigned. Moderate interobserver variability and little intraobserver variability in the interpretation of lesion significance were noted when an assessment classification similar to that of BI-RADS was used. Use of terms to describe calcifications did not always conform to BI-RADS-defined levels of suspicion.

CONCLUSION

BI-RADS is moderately successful in providing a standardized language for physicians to describe lesion morphology. Efforts to reevaluate specific terms and the diagnostic significance assigned to calcification descriptors may prove useful in maintaining the promise of improved quality with the BI-RADS standardized mammography lexicon.

摘要

目的

美国放射学会推荐使用乳腺影像报告和数据系统(BI-RADS)作为描述乳腺钼靶病变的标准化方案。本研究的目的是使用BI-RADS标准化词汇表来测量放射科医生对乳腺钼靶病变描述的观察者间和观察者内变异性。

材料与方法

由五名放射科医生对60份有异常发现的乳腺钼靶检查进行独立评估。阅片者从BI-RADS词汇表中为八个形态学类别中的每一个类别选择一个单一术语来描述每个病变:钙化分布、数量和描述;肿块边缘、形状和密度;相关发现;以及特殊情况。此外,每位阅片者用五点量表评估每个病变的重要性。一名观察者对每个病例阅读两次。使用Cohen's kappa统计量确定BI-RADS词汇表中每个描述和解释类别的观察者间和观察者内变异性。详细评估了放射科医生对钙化描述符的具体使用情况。

结果

在阅片者之间观察到在选择描述肿块和钙化的术语方面有实质性的一致性(kappa值范围为0.50±0.02 - 0.77±0.03)。这些类别的观察者内一致性相似(kappa值范围为0.57±0.07 - 0.84±0.09)。在“相关发现”和“特殊情况”类别中观察到相当大的观察者间和观察者内变异性(kappa值范围为 -0.02±0.14 - 0.38±0.12),这一结果部分反映了分配到这些类别的病例数量较少。当使用与BI-RADS类似的评估分类时,在病变重要性的解释方面观察到中度的观察者间变异性和较小的观察者内变异性。用于描述钙化的术语使用并不总是符合BI-RADS定义的可疑程度。

结论

BI-RADS在为医生提供描述病变形态的标准化语言方面取得了一定成功。重新评估特定术语以及赋予钙化描述符的诊断重要性的努力可能有助于维持BI-RADS标准化乳腺钼靶词汇表所带来的质量提升的前景。