实时三维超声心动图与时空图像相关技术在评估胎儿室间隔中的比较。

Comparison of real-time three-dimensional echocardiography and spatiotemporal image correlation in assessment of fetal interventricular septum.

作者信息

Xiong Yi, Liu Tao, Wu Ying, Xu Jing Feng, Ting Yuen Ha, Yeung Leung Tak, Lau Tze Kin

机构信息

Department of Obstetrics and Gynaecology, Fetal Medicine Unit, Prince of Wales Hospital, The Chinese University of Hong Kong, Hong Kong, China.

出版信息

J Matern Fetal Neonatal Med. 2012 Nov;25(11):2333-8. doi: 10.3109/14767058.2012.695822. Epub 2012 Jun 13.

Abstract

OBJECTIVE

To compare the role of real-time 3DE and STIC technology in assessment of the fetal IVS.

METHODS

Fifty pregnant women with singleton pregnancies were invited to attend this study. All the fetuses were examined by both spatiotemporal image correlation and real-time three-dimensional echocardiography. There were totally six images of IVS obtained for each fetus: live xPlane image, live 3D image, multiplanar image and rendered image with the four-chamber view as the starting plane, multiplanar image and rendered image with the sagittal view of the fetal thorax as the starting plane. These images were grouped into six groups and randomized within each group for the further analysis. The images were scored and compared according to the image quality, the outline of the fetal IVS and motion artefact. The operator was also asked to judge whether VSD existed or not and the results were compared with the final diagnosis. The sensitivity, specificity, false positive percentage, positive likelihood ratio, false negative percentage and negative likelihood ratio of each group were also calculated.

RESULTS

There were 15 cases with VSD and four cases without VSD in CHD fetus and 31 cases of normal fetus enrolled in this study. A total 300 images of the lateral view of fetal IVS were obtained and grouped into six groups. The image quality in the group of STIC with the four-chamber view as the starting plane is much worse than the group of STIC with the sagittal view as the starting plane and real-time three-dimensional echocardiography (P < 0.05). There were no significant differences in image quality between the group of STIC with the sagittal view as the starting plane and real-time three-dimensional echocardiography (P > 0.05).

CONCLUSION

The image quality of real-time 3DE is similar to the images acquired by STIC from the sagittal view and superior to that obtained by STIC from the four-chamber view. However, real-time 3DE has no motion artefact, which has the potentials to improve the detection rate of fetal VSD.

摘要

目的

比较实时三维超声(3DE)和时空关联成像(STIC)技术在评估胎儿室间隔(IVS)中的作用。

方法

邀请50名单胎孕妇参加本研究。所有胎儿均接受了时空关联成像和实时三维超声心动图检查。每个胎儿共获取6张IVS图像:以四腔心切面为起始平面的实时xPlane图像、实时三维图像、多平面图像和渲染图像,以及以胎儿胸部矢状切面为起始平面的多平面图像和渲染图像。这些图像被分为6组,并在每组内随机分组以进行进一步分析。根据图像质量、胎儿IVS轮廓和运动伪像对图像进行评分和比较。还要求操作者判断是否存在室间隔缺损(VSD),并将结果与最终诊断进行比较。计算每组的灵敏度、特异度、假阳性率、阳性似然比、假阴性率和阴性似然比。

结果

本研究纳入了15例患有先天性心脏病(CHD)且伴有VSD的胎儿、4例患有CHD但无VSD的胎儿以及31例正常胎儿。共获得300张胎儿IVS侧面观图像,并分为6组。以四腔心切面为起始平面的STIC组图像质量明显低于以矢状切面为起始平面的STIC组和实时三维超声心动图组(P < 0.05)。以矢状切面为起始平面的STIC组与实时三维超声心动图组在图像质量上无显著差异(P > 0.05)。

结论

实时3DE的图像质量与从矢状切面获取的STIC图像相似,且优于从四腔心切面获取的STIC图像。然而,实时3DE无运动伪像,有提高胎儿VSD检出率的潜力。