[NIOBI-X filter: reduction of patient exposure and effect on image quality].

作者信息

Rozza M, Campoleoni M, Landini A, Orsini S

机构信息

Servizio di Radiodiagnostica e Radioterapia, Istituto L. Mangiagalli, Milano.

出版信息

Radiol Med. 1990 Nov;80(5):740-4.

PMID:2267397
Abstract

Patient protection against ionizing radiation has become more and more important and the subject has been included in all the latest ICRP publications. Recently a 50 microns Niobium filter (NIOBI-X) has come out, which, installed on tungsten anode X-ray apparatuses, allows patient dose reduction by absorbing the radiation which does not contribute to the image. In order to verify the NIOBI-X actual effect on image quality and on patient dose reduction, image resolution, image contrast and patient exposure (air-Kerma) were measured using a bone-equivalent stepped wedge. The NIOBI-X, added to the total filtration of the X-ray apparatus, allows an air-Kerma reduction of about 50% from 60 to 130 kV. In the case of bone-equivalent material exposure the filter causes a slight contrast loss and does not affect, or even improves, image resolution. Before choosing the NIOBI-X filter for all the X-ray apparatuses a cost-benefit analysis should of course be made by evaluating results and cost related to other kinds of filter. With particular regard to Aluminium filters, whose prices are far lower than Niobium ones, it has to be pointed out that: 1) in order to have the same air-Kerma reduction the Aluminium filter thickness must be quite heavy (2.8 mm) which causes practical problems of use; 2) the Aluminium filter causes image quality loss especially at lower kVs.

摘要

相似文献

1
[NIOBI-X filter: reduction of patient exposure and effect on image quality].
Radiol Med. 1990 Nov;80(5):740-4.
2
[The use of copper and niobium filters in diagnostic x-ray equipment. A comparison of dose reduction, tube loading and picture quality].
Tidsskr Nor Laegeforen. 1990 Sep 20;110(22):2878-80.
3
An examination of automatic exposure control regimes for two digital radiography systems.对两种数字射线照相系统的自动曝光控制方案的研究。
Phys Med Biol. 2009 Aug 7;54(15):4645-70. doi: 10.1088/0031-9155/54/15/002. Epub 2009 Jul 10.
4
Niobium/aluminum filters reduce patient exposure.铌/铝过滤器可减少患者的辐射暴露。
Radiol Technol. 1992 Jan-Feb;63(3):170-5.
5
A fit method for the determination of inherent filtration with diagnostic x-ray units.
Phys Med Biol. 2006 May 21;51(10):2585-97. doi: 10.1088/0031-9155/51/10/015. Epub 2006 May 4.
6
Decrease in patient radiation exposure by a tantalum filter during electrophysiological procedures.
Pacing Clin Electrophysiol. 2009 Mar;32 Suppl 1:S109-12. doi: 10.1111/j.1540-8159.2008.02264.x.
7
Evaluation of the use of a niobium filter for patient dose reduction in chest radiography.
Br J Radiol. 1991 Apr;64(760):334-40. doi: 10.1259/0007-1285-64-760-334.
8
Effect of K-shell absorption edge filters on image quality in digital intraoral radiography.K 层吸收边缘滤过器对数字化口腔内放射成像图像质量的影响。
Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2000 Sep;90(3):377-84. doi: 10.1067/moe.2000.107532.
9
Ambient dose equivalent and effective dose from scattered x-ray spectra in mammography for Mo/Mo, Mo/Rh and W/Rh anode/filter combinations.钼/钼、钼/铑和钨/铑阳极/滤线器组合的乳腺摄影散射X射线光谱中的周围剂量当量和有效剂量。
Phys Med Biol. 2006 Apr 21;51(8):2077-91. doi: 10.1088/0031-9155/51/8/008. Epub 2006 Apr 3.
10
[Experimental investigations for dose reduction by optimizing the radiation quality for digital mammography with an a-Se detector].[利用非晶硒探测器优化数字乳腺摄影的辐射质量以降低剂量的实验研究]
Rofo. 2007 May;179(5):487-91. doi: 10.1055/s-2007-962983.