Department of Neurosurgery, Clinique du Parc Léopold, 38 rue Froissart, Brussels, Belgium.
J Neurointerv Surg. 2013 Sep 1;5(5):494-5. doi: 10.1136/neurintsurg-2012-010370. Epub 2012 Jun 7.
This prospective case-control study documents the level of radiation expected during percutaneous balloon compression of the Gasserian ganglion.
Percutaneous balloon compression of the Gasserian ganglion is a minimally invasive treatment for trigeminal neuralgia resistant to medical treatment and an alternative to microvascular decompression. This operation requires the use of fluoroscopy to navigate the needle through the foramen ovale and to monitor balloon inflation and deflation. However, the level of radiation exposure for this technique has never been reported. Exposure data (fluoroscopy time in seconds and radiation dose in mGycm(2)) were collected during 17 procedures on 14 patients using the dose report provided by the digital interface of the fluoroscope.
The mean fluoroscopy time per patient was 62 s, ranging from 102.9 s to 44.9 s, and the mean radiation dose per patient was 1137.18 mGycm(2), ranging from 1738 mGycm(2) to 639.5 mGycm(2).
This quantification of the dose and duration of radiation during percutaneous compression of the trigeminal ganglion shows that the amount of radiation required to perform this operation is significant and makes lead-coated protection clothing and careful use of the fluoroscope mandatory.
本前瞻性病例对照研究记录了经皮球囊压迫三叉神经节时预期的辐射水平。
经皮球囊压迫三叉神经节是一种治疗对药物治疗无效的三叉神经痛的微创方法,也是微血管减压术的替代方法。该手术需要使用透视来引导针穿过卵圆孔,并监测球囊的膨胀和收缩。然而,这种技术的辐射暴露水平从未有报道过。使用透视机数字接口提供的剂量报告,在 14 名患者的 17 次手术中收集了暴露数据(透视时间以秒为单位,剂量以 mGycm(2)为单位)。
每位患者的平均透视时间为 62 秒,范围为 102.9 秒至 44.9 秒,每位患者的平均辐射剂量为 1137.18 mGycm(2),范围为 1738 mGycm(2)至 639.5 mGycm(2)。
对经皮三叉神经节压迫术中剂量和辐射时间的这种量化表明,进行这项操作所需的辐射量是显著的,这使得必须使用铅涂层防护服和仔细使用透视机。