Déglon Julien, Versace François, Lauer Estelle, Widmer Christèle, Mangin Patrice, Thomas Aurélien, Staub Christian
Unit of Toxicology, University Center of Legal Medicine, Rue Michel-Servet 1, CH-1211 Geneva 4, Switzerland.
Bioanalysis. 2012 Jun;4(11):1337-50. doi: 10.4155/bio.12.42.
Dried blood spots (DBS) sampling has gained popularity in the bioanalytical community as an alternative to conventional plasma sampling, as it provides numerous benefits in terms of sample collection and logistics. The aim of this work was to show that these advantages can be coupled with a simple and cost-effective sample pretreatment, with subsequent rapid LC-MS/MS analysis for quantitation of 15 benzodiazepines, six metabolites and three Z-drugs. For this purpose, a simplified offline procedure was developed that consisted of letting a 5-µl DBS infuse directly into 100 µl of MeOH, in a conventional LC vial.
The parameters related to the DBS pretreatment, such as extraction time or internal standard addition, were investigated and optimized, demonstrating that passive infusion in a regular LC vial was sufficient to quantitatively extract the analytes of interest. The method was validated according to international criteria in the therapeutic concentration ranges of the selected compounds.
The presented strategy proved to be efficient for the rapid analysis of the selected drugs. Indeed, the offline sample preparation was reduced to a minimum, using a small amount of organic solvent and consumables, without affecting the accuracy of the method. Thus, this approach enables simple and rapid DBS analysis, even when using a non-DBS-dedicated autosampler, while lowering the costs and environmental impact.
干血斑(DBS)采样作为传统血浆采样的一种替代方法,在生物分析领域越来越受欢迎,因为它在样品采集和物流方面具有诸多优势。本研究的目的是表明,这些优势可以与简单且经济高效的样品预处理相结合,随后进行快速液相色谱-串联质谱(LC-MS/MS)分析,以定量测定15种苯二氮䓬类药物、6种代谢物和3种Z类药物。为此,开发了一种简化的离线程序,即在常规液相色谱小瓶中,将5微升干血斑直接注入100微升甲醇中。
对与干血斑预处理相关的参数,如萃取时间或内标添加量进行了研究和优化,结果表明在常规液相色谱小瓶中进行被动注入足以定量萃取目标分析物。该方法在所选化合物的治疗浓度范围内按照国际标准进行了验证。
所提出的策略被证明对于所选药物的快速分析是有效的。事实上,离线样品制备被降至最低限度,使用少量有机溶剂和耗材,且不影响方法的准确性。因此,即使使用非专用干血斑自动进样器,这种方法也能实现简单快速的干血斑分析,同时降低成本和环境影响。