Private Orthodontic Practice, Schaumburg, IL 60914, USA.
J Dent. 2012 Oct;40(10):787-92. doi: 10.1016/j.jdent.2012.05.012. Epub 2012 Jun 18.
The purpose of this study was to examine the flexure strength (σ) and fracture toughness (K(IC)) of three indirect dental composites (dentin, body, and incisal) with respect to loading (static and cyclic), testing environments (air and water) and ageing (0 (controls) and 6 months in air and water).
The specimens were 3 mm × 3 mm × 25 mm bars with the fracture toughness specimens having a 0.75 mm notch machined in the midspan. Static testing utilized 15 bars and cyclic testing 25 bars for each testing variable. All bars were tested using three-point loading and the cyclic testing was for 1000 cycles using a staircase approach.
For flexure strength and fracture toughness, all specimen groups showed a decrease in mean values when exposed to cyclic loading as compared to the static loading mean and when exposed to ageing compared to the control specimens. ANOVA analysis demonstrated that dentin specimens had higher flexure strength and fracture toughness means than incisal and body specimens and that control and water specimens had higher flexure strength and fracture toughness means than aged and air specimens.
Degradation of these materials, as a result of cyclic loading and ageing in an aqueous environment, appears to be influenced by more than just the processing of the composite.
本研究旨在考察三种间接牙科复合材料(牙本质、体部和切端)在静态和循环加载、测试环境(空气和水)以及老化(对照和空气和水中 6 个月)方面的挠曲强度(σ)和断裂韧性(KIC)。
试件为 3mm×3mm×25mm 棒材,其中断裂韧性试件在中跨处加工了 0.75mm 的缺口。静态测试使用了 15 个棒材,循环测试使用了 25 个棒材,每个测试变量各有 25 个棒材。所有棒材均采用三点加载进行测试,循环测试采用阶梯式方法进行 1000 次循环。
对于挠曲强度和断裂韧性,与静态加载平均值相比,所有试件组在经受循环加载时,以及与对照试件相比,在经受老化时,平均值均下降。方差分析表明,牙本质试件的挠曲强度和断裂韧性平均值高于切端和体部试件,而对照和水试件的挠曲强度和断裂韧性平均值高于老化和空气试件。
这些材料的降解,由于循环加载和水环境中的老化,似乎不仅仅受到复合材料加工的影响。