To compare the speech perception benefit, provided by a contralateral hearing aid (HA) or a second cochlear implant (CI).
Repeated measures.
A total of 25 adult subjects participated in the study, including 12 bilateral (10 female and 2 male patients) and 13 bimodal (6 female and 7 male subjects) users. All bilateral users were sequentially implanted. The bimodal users were separated into a poor group (n = 5, aided pure-tone average (PTA) of 55 dB HL or greater at audiometric frequencies of 1 kHz or lesser) and a good group (n = 8, aided PTA < 55 dB HL).
Consonant, vowel, and sentence recognition was measured in quiet and noise at +5 dB and +10 dB signal-to-noise ratios (SNRs). Speech recognition performance was evaluated under three listening conditions: CI alone, HA alone, and CI+HA for bimodal users; first CI alone, second CI alone, and first CI + second CI for bilateral users when speech and noise were presented from the front.
There was no significant difference in the binaural benefit between the good bimodal and bilateral groups in vowel and sentence recognition. However, the binaural benefit is significantly better in the bilateral group than in the poor bimodal group for all 3 speech measures.
These results suggest that the aided pure-tone average at audiometric frequencies of 1 kHz or lesser may serve as one of the clinical criteria for the recommendation of whether bimodal patients should consider a second cochlear implant to maximize their binaural listening ability.
比较对侧助听器(HA)或第二个人工耳蜗(CI)提供的言语感知益处。
重复测量。
共有 25 名成年受试者参加了这项研究,包括 12 名双侧(10 名女性和 2 名男性患者)和 13 名双侧(6 名女性和 7 名男性受试者)使用者。所有双侧使用者均连续植入。双侧使用者分为差组(n=5,助听听阈纯音平均值(PTA)在 1 kHz 或更低频率的听力频率为 55 dB HL 或更高)和优组(n=8,助听听阈 <55 dB HL)。
在安静和噪声环境下,以+5 dB 和+10 dB 信噪比(SNR)测量辅音、元音和句子识别。在三种听力条件下评估言语识别性能:双侧使用者为 CI 单独、HA 单独和 CI+HA;当言语和噪声从前侧呈现时,双侧使用者为第一 CI 单独、第二 CI 单独和第一 CI+第二 CI。
在元音和句子识别方面,优组和双侧组的双耳优势无显著差异。然而,对于所有 3 种言语测量,双侧组的双耳优势明显优于差组。
这些结果表明,1 kHz 或更低频率的助听听阈纯音平均值可能是推荐双侧患者是否应考虑第二个人工耳蜗以最大程度提高双耳聆听能力的临床标准之一。