双耳聆听患者植入第二侧人工耳蜗的临床选择标准。

Clinical selection criteria for a second cochlear implant for bimodal listeners.

机构信息

Division of Communication and Neuroscience, House Research Institute, Los Angeles, California 90057, USA.

出版信息

Otol Neurotol. 2012 Sep;33(7):1161-8. doi: 10.1097/MAO.0b013e318259b8c0.

Abstract

OBJECTIVE

To compare the speech perception benefit, provided by a contralateral hearing aid (HA) or a second cochlear implant (CI).

STUDY DESIGN

Repeated measures.

PATIENTS

A total of 25 adult subjects participated in the study, including 12 bilateral (10 female and 2 male patients) and 13 bimodal (6 female and 7 male subjects) users. All bilateral users were sequentially implanted. The bimodal users were separated into a poor group (n = 5, aided pure-tone average (PTA) of 55 dB HL or greater at audiometric frequencies of 1 kHz or lesser) and a good group (n = 8, aided PTA < 55 dB HL).

MAIN OUTCOME MEASURES

Consonant, vowel, and sentence recognition was measured in quiet and noise at +5 dB and +10 dB signal-to-noise ratios (SNRs). Speech recognition performance was evaluated under three listening conditions: CI alone, HA alone, and CI+HA for bimodal users; first CI alone, second CI alone, and first CI + second CI for bilateral users when speech and noise were presented from the front.

RESULTS

There was no significant difference in the binaural benefit between the good bimodal and bilateral groups in vowel and sentence recognition. However, the binaural benefit is significantly better in the bilateral group than in the poor bimodal group for all 3 speech measures.

CONCLUSION

These results suggest that the aided pure-tone average at audiometric frequencies of 1 kHz or lesser may serve as one of the clinical criteria for the recommendation of whether bimodal patients should consider a second cochlear implant to maximize their binaural listening ability.

摘要

目的

比较对侧助听器(HA)或第二个人工耳蜗(CI)提供的言语感知益处。

研究设计

重复测量。

患者

共有 25 名成年受试者参加了这项研究,包括 12 名双侧(10 名女性和 2 名男性患者)和 13 名双侧(6 名女性和 7 名男性受试者)使用者。所有双侧使用者均连续植入。双侧使用者分为差组(n=5,助听听阈纯音平均值(PTA)在 1 kHz 或更低频率的听力频率为 55 dB HL 或更高)和优组(n=8,助听听阈 <55 dB HL)。

主要观察指标

在安静和噪声环境下,以+5 dB 和+10 dB 信噪比(SNR)测量辅音、元音和句子识别。在三种听力条件下评估言语识别性能:双侧使用者为 CI 单独、HA 单独和 CI+HA;当言语和噪声从前侧呈现时,双侧使用者为第一 CI 单独、第二 CI 单独和第一 CI+第二 CI。

结果

在元音和句子识别方面,优组和双侧组的双耳优势无显著差异。然而,对于所有 3 种言语测量,双侧组的双耳优势明显优于差组。

结论

这些结果表明,1 kHz 或更低频率的助听听阈纯音平均值可能是推荐双侧患者是否应考虑第二个人工耳蜗以最大程度提高双耳聆听能力的临床标准之一。

相似文献

6
Mandarin speech perception in combined electric and acoustic stimulation.电刺激与声刺激联合作用下的普通话语音感知
PLoS One. 2014 Nov 11;9(11):e112471. doi: 10.1371/journal.pone.0112471. eCollection 2014.

引用本文的文献

本文引用的文献

1
Speech recognition and acoustic features in combined electric and acoustic stimulation.联合电声刺激中的语音识别和声学特征。
J Speech Lang Hear Res. 2012 Feb;55(1):105-24. doi: 10.1044/1092-4388(2011/10-0325). Epub 2011 Dec 22.
6
Hybrid 10 clinical trial: preliminary results.混合10临床试验:初步结果。
Audiol Neurootol. 2009;14 Suppl 1(Suppl 1):32-8. doi: 10.1159/000206493. Epub 2009 Apr 22.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验