Suppr超能文献

通过人工耳蜗和传统助听器进行双耳刺激所带来的双耳听力优势:一项为期6个月的对比研究。

Advantages of binaural hearing provided through bimodal stimulation via a cochlear implant and a conventional hearing aid: a 6-month comparative study.

作者信息

Morera C, Manrique M, Ramos A, Garcia-Ibanez L, Cavalle L, Huarte A, Castillo C, Estrada E

机构信息

ENT Department Universitary Hospital La Fe, University of Valencia, Spain.

出版信息

Acta Otolaryngol. 2005 Jun;125(6):596-606. doi: 10.1080/00016480510027493.

Abstract

CONCLUSIONS

Our study data demonstrate the additional benefit derived from continued use of a contralateral hearing aid (HA) post-cochlear implantation for speech recognition ability in quiet and in noise. Postoperative bimodal stimulation is recommended for all subjects who show some speech recognition ability in the contralateral ear as it may offer binaural listening advantages in various listening situations encountered in everyday life.

OBJECTIVES

To assess the benefits derived from bimodal stimulation for experienced HA users implanted with a cochlear implant (CI) (score=20% in disyllabic test). The correlation between pre- and postoperative performance on speech perception measures was examined to determine additional criteria for recommending bimodal stimulation postoperatively.

MATERIAL AND METHODS

A within-subject repeated-measures design was used, with each subject acting as their own control. Assessments were carried out preoperatively in aided monaural and best-aided conditions and at 6 months postoperatively in CI-alone, contralateral HA-alone and bimodal listening conditions. Speech recognition using Spanish words and sentences materials was assessed at conversational level and for soft speech in quiet. Speech comprehension in noise was assessed using word materials at a signal:noise ratio of +10, for coincident speech in noise and for spatially separated speech in noise. Twelve adult native Spanish subjects with a severe-to-profound hearing impairment who were experienced with optimally fitted conventional amplification and who displayed suboptimal speech understanding preoperatively were enrolled in the study. Preoperatively, conventional amplification was worn by five subjects binaurally and by seven monaurally.

RESULTS

Postoperatively, superior speech recognition ability in quiet and in noise for disyllabic words was achieved using bimodal stimulation in comparison to performance for either monaural aided condition. Mean improvement in speech recognition in the bimodal condition was significant over performance in the CI-alone condition for disyllabic words in quiet at 70 (p=0.006) and 55 dB SPL (p=0.028), for disyllabic words in noise at +10 dB with speech and noise spatially separated with the noise source closest to the contralateral HA (S0NHA) (p=0.0005) and when the noise source was closest to the CI ear (S0NCI) (p=0.002). When testing word recognition in noise with speech and noise sources coincident in space, word scores were superior in the bimodal condition relative to the CI-alone condition but this improvement was not significant (p=0.07). The advantages of bimodal stimulation included significant effects of binaural summation in quiet and significant binaural squelch effects in both the S0NHA and S0NCI test conditions. All subjects showed superior performance in the binaural situation postoperatively relative to the best-aided condition preoperatively for one or more test situations.

摘要

结论

我们的研究数据表明,人工耳蜗植入术后继续使用对侧助听器(HA)可在安静环境和噪声环境中提高言语识别能力。对于对侧耳有一定言语识别能力的所有受试者,建议术后进行双模式刺激,因为这可能在日常生活中遇到的各种聆听情况下提供双耳聆听优势。

目的

评估双模式刺激对植入人工耳蜗(CI)的有经验的HA使用者(双音节测试得分=20%)的益处。研究术前和术后言语感知测量结果之间的相关性,以确定术后推荐双模式刺激的其他标准。

材料与方法

采用受试者内重复测量设计,每个受试者作为自己的对照。术前在助听单耳和最佳助听条件下进行评估,术后6个月在单独使用CI、单独使用对侧HA和双模式聆听条件下进行评估。使用西班牙语单词和句子材料在对话水平和安静环境下的轻声言语中评估言语识别。使用单词材料在信号:噪声比为+10时评估噪声中的言语理解,包括噪声中同时出现的言语和噪声中空间分离的言语。12名患有严重至极重度听力损失的成年西班牙母语受试者参与了本研究,他们有使用最佳适配传统放大设备的经验,且术前言语理解能力欠佳。术前,5名受试者双耳佩戴传统放大设备,7名单耳佩戴。

结果

术后,与单耳助听条件下的表现相比,双模式刺激在安静环境和噪声环境中对双音节单词的言语识别能力更强。在安静环境中,对于70 dB SPL(p=0.006)和55 dB SPL(p=0.028)的双音节单词,双模式条件下言语识别的平均改善相对于单独使用CI条件下的表现具有显著差异;在噪声环境中,对于言语和噪声空间分离且噪声源最靠近对侧HA(S0NHA)(p=0.0005)以及噪声源最靠近CI耳(S0NCI)(p=0.002)时+10 dB的双音节单词,双模式条件下言语识别的平均改善相对于单独使用CI条件下的表现具有显著差异。当测试言语和噪声源在空间上重合时噪声中的单词识别时,双模式条件下的单词得分相对于单独使用CI条件更优,但这种改善不显著(p=0.07)。双模式刺激的优势包括在安静环境中双耳总和的显著效应以及在S0NHA和S0NCI测试条件下的显著双耳抑制效应。所有受试者在术后的双耳情况下相对于术前最佳助听条件下的一种或多种测试情况表现更优。