Suppr超能文献

口腔内放射摄影屏蔽计算中修正因子的建议。

Proposals for revised factors in intra-oral radiography shielding calculations.

作者信息

Worrall M, McVey S, Sutton D G

机构信息

Radiation Physics, Department of Medical Physics, Ninewells Hospital and Medical School, Dundee DD1 9SY, UK.

出版信息

J Radiol Prot. 2012 Sep;32(3):243-9. doi: 10.1088/0952-4746/32/3/243. Epub 2012 Jul 19.

Abstract

The current value for weighted average primary plus scatter kerma at 1 m for intra-oral radiography shielding assessment is based on scatter radiation measurements made with the trunk of a RANDO phantom and an assessment of primary transmission that is unverified. Measurements of primary transmission and scatter radiation during intra-oral radiography were made at 30° intervals through a full 360° rotation using two anthropomorphic head phantoms and similar equipment at three different sites. The results suggest that a scatter factor of 5 µGy (Gy cm(2))(-1) and a primary transmission of 0.03% of the entrance surface dose are more appropriate and, therefore, we recommend that the weighted average primary plus scatter kerma used for shielding calculations can be reduced from 1 to 0.5 µGy per exposure at 1 m. This factor will adequately account for exposures made at 60 and 70 kV using a range of intra-oral units.

摘要

口腔内放射摄影屏蔽评估中,1米处加权平均原发射线加散射比释动能的当前值是基于使用RANDO体模躯干进行的散射辐射测量以及未经证实的原发射线透射评估得出的。在三个不同地点,使用两个仿真人头模和类似设备,通过360°全旋转以30°间隔进行了口腔内放射摄影期间的原发射线透射和散射辐射测量。结果表明,5 µGy (Gy cm²)⁻¹ 的散射因子和入射表面剂量0.03%的原发射线透射更为合适,因此,我们建议用于屏蔽计算的加权平均原发射线加散射比释动能可从每1米处每次曝光1 µGy降至0.5 µGy。该因子将充分考虑使用一系列口腔内设备在60和70 kV下进行的曝光。

相似文献

5
Efficacy of lower-body shielding in computed tomography fluoroscopy-guided interventions.下肢屏蔽在 CT 透视引导介入中的效果。
Cardiovasc Intervent Radiol. 2012 Dec;35(6):1475-9. doi: 10.1007/s00270-011-0338-0. Epub 2012 Jan 10.
9
Shielding requirements in helical tomotherapy.螺旋断层放射治疗中的屏蔽要求。
Phys Med Biol. 2007 Aug 21;52(16):5057-67. doi: 10.1088/0031-9155/52/16/023. Epub 2007 Aug 1.
10
Methods for monitoring patient dose in dental radiology.牙科放射学中患者剂量监测方法。
Radiat Prot Dosimetry. 2010 Apr-May;139(1-3):303-5. doi: 10.1093/rpd/ncq095. Epub 2010 Mar 11.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验