[一例由心内膜电极导致的三尖瓣医源性缺损病例]

[A case of a iatrogenic defect of the tricuspid valve caused by endocardial electrodes].

作者信息

Egorov D F, Sapozhnikov I R, Domashenko A A, Gandina I A, Smirin S D, Vasil'ev S G

出版信息

Arkh Patol. 1990;52(10):61-3.

PMID:2281978
Abstract

One case of a rare complication of the permanent heart electrostimulation is observed among many patients treated with such method for many years. A 77-year-old man having a permanent electrostimulation during 13 years because of a complete atrioventricular heart blockade, developed a defect of the tricuspid valve resulting from two endocardial electrodes. Narrowing of the right atrioventricular aperture and a severe dilatation of the right atrium worsened the circulation deficiency. More frequent use of various methods of the nonfunctioning endocardial electrode elimination is recommended. Transvenous destruction of the fibrous capsule at the end of endocardial electrodes is an efficient method developed by the authors for their elimination.

摘要

在多年来接受这种方法治疗的众多患者中,观察到一例永久性心脏电刺激的罕见并发症。一名77岁男性因完全性房室传导阻滞接受了13年的永久性电刺激治疗,因两根心内膜电极导致三尖瓣缺损。右房室口狭窄和右心房严重扩张使循环功能不全恶化。建议更频繁地使用各种方法消除无功能的心内膜电极。心内膜电极末端纤维囊的经静脉破坏是作者开发的一种有效的消除方法。

相似文献

1
[A case of a iatrogenic defect of the tricuspid valve caused by endocardial electrodes].[一例由心内膜电极导致的三尖瓣医源性缺损病例]
Arkh Patol. 1990;52(10):61-3.
2
[Extraction of tricuspid valve tissue and myocardium as a complication of transvenous cardiac pacing (author's transl)].经静脉心脏起搏并发症之三尖瓣组织及心肌提取(作者译)
Thoraxchir Vask Chir. 1977 Apr;25(2):97-100. doi: 10.1055/s-0028-1096689.
3
[Alternatives to chronic cardiac stimulation in patients with mechanical tricuspid prosthesis and atrioventricular block].[机械性三尖瓣假体和房室传导阻滞患者慢性心脏刺激的替代方法]
Arch Cardiol Mex. 2002 Jul-Sep;72(3):233-9.
4
[Fracture of endocardial electrode at the tricuspid valve level].
Arq Bras Cardiol. 1992 Jan;58(1):41-2.
5
[Two adult cases with corrected transposition of the great arteries treated with permanent endocardial pacemaker implantation].[两例经皮永久心内膜起搏器植入治疗的矫正型大动脉转位成人病例]
Kokyu To Junkan. 1993 Aug;41(8):791-5.
6
Avulsion of a tricuspid valve leaflet during traction on an infected, entrapped endocardial pacemaker electrode. The role of electrode design.在牵引感染、嵌顿的心内膜起搏器电极时三尖瓣小叶撕裂。电极设计的作用。
J Thorac Cardiovasc Surg. 1977 Sep;74(3):433-5.
7
[Perforation of tricuspid valve and pulmonary embolism as a complication of intracardiac stimulation].[三尖瓣穿孔及肺栓塞作为心内刺激的并发症]
Kardiol Pol. 1972;15(3):339-42.
8
Severe symptomatic tricuspid valve regurgitation due to permanent pacemaker or implantable cardioverter-defibrillator leads.永久性起搏器或植入式心脏复律除颤器导线导致的严重症状性三尖瓣反流
J Am Coll Cardiol. 2005 May 17;45(10):1672-5. doi: 10.1016/j.jacc.2005.02.037.
9
Tricuspid valve stenosis caused by fibrous adhesions to an endocardial pacemaker lead in a dog.犬因心内膜起搏器导线纤维粘连导致的三尖瓣狭窄。
J Vet Cardiol. 2007 Nov;9(2):123-8. doi: 10.1016/j.jvc.2007.07.001.
10
Perforation of the tricuspid valve caused by an implanted device lead.
Eur Heart J Cardiovasc Imaging. 2013 Dec;14(12):1186. doi: 10.1093/ehjci/jet113. Epub 2013 Jun 13.