School of Kinesiology, University of British Columbia, Vancouver, Canada.
Arch Phys Med Rehabil. 2012 Dec;93(12):2367-72. doi: 10.1016/j.apmr.2012.07.008. Epub 2012 Jul 25.
(1) To quantify the intra- and intersession reliability and minimal detectable change (MDC) of the SmartWheel clinical protocol (SCP) and (2) to compare the reliability of the SCP between experienced and naïve wheelchair users.
Test-retest study.
Biomechanics laboratory.
Manual wheelchair users (WCUs) (n=10) with 1 to 32 years of wheeling experience and able-bodied (AB) naïve users (n=15).
Not applicable.
Wheelchair propulsion parameters including average peak force, push frequency, push length, and velocity were measured according to the SCP but with 5 trials per session, for 2 sessions. WCUs and AB users were analyzed separately. Intraclass correlation coefficients (ICC and ICC(2,5)) were calculated to assess intrasession reliability. ICC(2,1) and MDC (with 95% confidence) were calculated for each SCP parameter using a single trial from each session and with the mean of 5 repeated measures to evaluate intersession reliability.
Intra- and intersession reliability for WCU parameters ranged from high to very high correlation (ICC range, .70-.99). For AB parameters, intrasession ICC(2,1) ranged from moderate to very high (ICC range, .50-.92), while intersession ICC(2,1) indicated low to very high correlation (ICC range, .25-.90). Estimates of standard error of measurement and MDC were provided for each parameter. For both WCUs and AB users, using the means from 5 trials increased intra- and intersession ICC and decreased MDC values. All MDC values were lower for WCUs compared with AB users.
The SCP is a reliable method for assessing propulsion parameters in WCUs, even if just 1 trial is taken per session. AB users showed lower intra- and intersession reliability compared with WCUs. Therefore, for AB users or individuals with minimal wheeling experience, averaging multiple trials is recommended for the SCP.
(1) 量化 SmartWheel 临床方案(SCP)的内和间测试可靠性和最小可检测变化(MDC);(2) 比较有经验和无经验的轮椅使用者之间 SCP 的可靠性。
测试-重测研究。
生物力学实验室。
有 1 至 32 年轮椅使用经验的手动轮椅使用者(WCU)(n=10)和无经验的健全(AB)使用者(n=15)。
不适用。
根据 SCP 测量轮椅推进参数,包括平均峰值力、推动频率、推动长度和速度,但每次测试 5 次,共 2 次测试。分别分析 WCU 和 AB 用户。计算组内相关系数(ICC和 ICC(2,5))以评估日内可靠性。使用每个会话的单次试验和 5 次重复测量的平均值计算每个 SCP 参数的 ICC(2,1)和 MDC(95%置信区间),以评估间测试可靠性。
WCU 参数的日内和间测试可靠性从高到非常高相关(ICC 范围,.70-.99)。对于 AB 参数,日内 ICC(2,1)范围从中度到非常高(ICC 范围,.50-.92),而间 ICC(2,1)则表示低到非常高的相关性(ICC 范围,.25-.90)。为每个参数提供了测量误差的标准误差和 MDC 的估计值。对于 WCU 和 AB 用户,使用 5 次试验的平均值会增加日内和间测试的 ICC 值并降低 MDC 值。与 AB 用户相比,所有 MDC 值均较低。
即使每次测试仅使用 1 次,SCP 也是评估 WCU 推进参数的可靠方法。与 WCU 相比,AB 用户的日内和间测试可靠性较低。因此,对于 AB 用户或仅具有最低轮椅使用经验的个体,建议对 SCP 进行多次试验的平均值。