Jyothi Kn, Crasta Shanol, Venugopal P
Department of Conservative Dentistry and Endodontics, Sri Siddhartha Dental College, Tumkur, Karnataka, India.
J Conserv Dent. 2012 Jul;15(3):214-7. doi: 10.4103/0972-0707.97938.
This in vitro study was designed to comparatively evaluate the effect of five commercial mouth rinses on the micro hardness of a nanofilled resin based restorative material.
Fifty specimens of resin composite material (Filtek Z350XT, 3M ESPE, St.Paul, MN USA) were prepared and immersed in artificial saliva for 24 h. The base line micro hardness of specimens was recorded using Vicker's micro hardness tester (MMT - X7 Matsuzawa, Japan). The specimens were randomly distributed into five groups, each containing 10 specimens (n=10) as follows - Group I Listerine (alcohol based), Group II Periogard (alcohol based), Group III Colgate plax (alcohol based), Group IV C- prev (alcohol free), Group V Hiora(alcohol free). The specimens were immersed in 20 ml of mouth rinses and incubated for 24 h at 37°C. The post immersion micro hardness values of the specimens were recorded and the data was tabulated for statistical analysis. Kruskal-Wallis test was used for inter group comparison followed by pair wise comparison of groups using Mann-Whitney U test. The level of significance was set at P=0.05.
Significant reduction in the mean VHN (Vicker's micro hardness number) was observed in all the groups after exposure to the tested mouth rinses (P<0.01) and the reduction in mean VHN values were as follows: Group I 12.09, Group II 3.42, Group II 1.51, Group IV 1.03, Group V 0.57. Inter group comparison showed statistically significant reduction in micro hardness in Groups I and II compared to all other groups with P<0.001. There was no significant difference between Groups III, IV and V.
All the mouth rinses showed a reduction in the microhardness of nanofilled resin composite material with listerine (Group I) containing maximum amount of alcohol, showing highest reduction in micro hardness value.
本体外研究旨在比较评估五种市售漱口水对纳米填充树脂基修复材料显微硬度的影响。
制备五十个树脂复合材料样本(Filtek Z350XT,3M ESPE,美国明尼苏达州圣保罗),并将其浸入人工唾液中24小时。使用维氏显微硬度测试仪(MMT - X7,日本松泽)记录样本的基线显微硬度。样本被随机分为五组,每组包含10个样本(n = 10),如下所示:第一组为李施德林(含酒精),第二组为派丽奥(含酒精),第三组为高露洁全效(含酒精),第四组为C - prev(不含酒精),第五组为皓乐齿(不含酒精)。将样本浸入20毫升漱口水,于37°C孵育24小时。记录样本浸泡后的显微硬度值,并将数据列表进行统计分析。采用Kruskal - Wallis检验进行组间比较,随后使用Mann - Whitney U检验进行组间两两比较。显著性水平设定为P = 0.05。
在接触测试漱口水后,所有组的平均维氏硬度数(VHN)均显著降低(P < 0.01),平均VHN值降低情况如下:第一组12.09,第二组3.42,第三组1.51,第四组1.03,第五组0.57。组间比较显示,与所有其他组相比,第一组和第二组的显微硬度在统计学上显著降低,P < 0.001。第三组、第四组和第五组之间无显著差异。
所有漱口水均使纳米填充树脂复合材料的显微硬度降低,含酒精量最高的李施德林(第一组)使显微硬度值降低最多。