Suppr超能文献

葡萄中二氧化硫的测定:莫尼尔-威廉姆斯法与两种离子排斥色谱法的比较

Determination of sulfur dioxide in grapes: comparison of the Monier-Williams method and two ion exclusion chromatographic methods.

作者信息

Kim H J, Conca K R, Richardson M J

机构信息

U.S. Army Natick Research, Development and Engineering Center, Food Engineering Directorate, Natick, MA 01760.

出版信息

J Assoc Off Anal Chem. 1990 Nov-Dec;73(6):983-9.

PMID:2289930
Abstract

Results for determination of sulfur dioxide in grapes were compared by 3 methods: the modified Monier-Williams method, acid distillation/ion exclusion chromatography with electrochemical detection (AD/IEC-EC), and alkali extraction/ion exclusion chromatography with electrochemical detection (AE/IEC-EC). An unusual positive response was observed during the later stage of the Monier-Williams distillation of both control grapes and sulfited grapes. Development of volatile acidic compounds in parallel with this Monier-Williams response and darkening of sample was also observed by collection in an alkali trap and analysis using anion exclusion chromatography and photodiode array detection. No parallel increase in sulfite was observed by the more selective AD/IEC-EC method, which clearly demonstrated that the response observed during the later stage of the Monier-Williams method is a false positive, probably due to caramelization reaction products. Monier-Williams results for grapes containing ca 10 ppm sulfite were in reasonably good agreement with those by either the AD/IEC-EC or AE/IEC-EC methods, presumably because the false positive response in the Monier-Williams analysis compensated for the somewhat incomplete recovery of sulfite. The AE/IEC-EC method is recommended because it is rapid, sensitive, straightforward, and free from interference. Accurate results by Monier-Williams analysis could be obtained by limiting distillation to 60 min and correcting for recovery.

摘要

采用3种方法比较了葡萄中二氧化硫的测定结果:改良的莫尼尔-威廉姆斯法、酸蒸馏/离子排斥色谱-电化学检测法(AD/IEC-EC)和碱萃取/离子排斥色谱-电化学检测法(AE/IEC-EC)。在对照葡萄和亚硫酸盐处理葡萄的莫尼尔-威廉姆斯蒸馏后期均观察到异常的阳性响应。通过在碱阱中收集并使用阴离子排斥色谱和光电二极管阵列检测进行分析,还观察到与这种莫尼尔-威廉姆斯响应同时出现的挥发性酸性化合物的产生以及样品变黑。选择性更强的AD/IEC-EC方法未观察到亚硫酸盐的平行增加,这清楚地表明在莫尼尔-威廉姆斯法后期观察到的响应是假阳性,可能是由于焦糖化反应产物所致。对于含约10 ppm亚硫酸盐的葡萄,莫尼尔-威廉姆斯法的结果与AD/IEC-EC法或AE/IEC-EC法的结果相当吻合,推测是因为莫尼尔-威廉姆斯分析中的假阳性响应弥补了亚硫酸盐回收的不完全。推荐使用AE/IEC-EC方法,因为它快速、灵敏、直接且无干扰。通过将蒸馏限制在60分钟并校正回收率,可以获得莫尼尔-威廉姆斯分析的准确结果。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验