Wu Tongning, Tan Liwen, Shao Qing, Li Ying, Yang Lei, Zhao Chen, Xie Yi, Zhang Shaoxiang
China Academy of Telecommunication Research of Ministry of Industry and Information Technology, No. 52, Huayuanbei Road, Beijing 100191, China.
Radiat Prot Dosimetry. 2013 Apr;154(1):31-6. doi: 10.1093/rpd/ncs141. Epub 2012 Aug 17.
Standing Chinese adult anatomical models are obtained from supine-postured cadaver slices. This paper presents the dosimetric differences between the supine and the standing postures over wide band frequencies and various incident configurations. Both the body level and the tissue/organ level differences are reported for plane wave and the 3T magnetic resonance imaging radiofrequency electromagnetic field exposure. The influence of posture on the whole body specific absorption rate and tissue specified specific absorption rate values is discussed.
站立位中国成人解剖模型是从仰卧位尸体切片获得的。本文介绍了仰卧位和站立位在宽带频率和各种入射配置下的剂量学差异。报告了平面波和3T磁共振成像射频电磁场暴露下身体层面和组织/器官层面的差异。讨论了姿势对全身比吸收率和组织比吸收率值的影响。