J Chromatogr A. 2012 Sep 28;1257:34-40. doi: 10.1016/j.chroma.2012.07.048. Epub 2012 Jul 25.
The performance of HPLC-UV as a means of quantifying selected furocoumarins in essential oils has been evaluated, based on a ring test validation approach. Accuracy profiles were generated, to determine bias and statistical confidence associated with determination at different concentrations, along with lower limits of quantification (LOQ). From these findings, it can be concluded that the method described may only be used in simple cases (essential oils), to measure individual furocoumarin compounds at concentrations greater than 10mg/l; the non compound-specific nature of detection by absorption in the UV range is unable to overcome the effect of interferences arising from chromatographic coelutions, such as those encountered in the analysis of complex commercial fragrance mixtures. The use of an algorithmically calculated 'spectral similarity' function, with reference to authentic standards, may be used to improve reliability in assignment and quantification.
已基于环试验验证方法评估了 HPLC-UV 作为定量精油中所选呋喃香豆素的手段的性能。生成了准确度概况,以确定在不同浓度下测定时的偏差和统计置信度,以及定量下限 (LOQ)。从这些发现中可以得出结论,所描述的方法可能仅适用于简单情况(精油),以在浓度大于 10mg/l 的情况下测量单个呋喃香豆素化合物;通过在 UV 范围内吸收进行非化合物特异性检测,无法克服色谱共洗脱引起的干扰的影响,例如在分析复杂的商业香精混合物时遇到的干扰。使用算法计算的“光谱相似度”函数,并参考真实标准,可用于提高分配和定量的可靠性。