Luyckx T, Peeters T, Vandenneucker H, Victor J, Bellemans J
University Hospitals UZ Leuven, Weligerveld 1, 3212 Pellenberg, Belgium.
J Bone Joint Surg Br. 2012 Sep;94(9):1271-6. doi: 10.1302/0301-620X.94B9.28670.
Obtaining a balanced flexion gap with correct femoral component rotation is one of the prerequisites for a successful outcome after total knee replacement (TKR). Different techniques for achieving this have been described. In this study we prospectively compared gap-balancing versus measured resection in terms of reliability and accuracy for femoral component rotation in 96 primary TKRs performed in 96 patients using the Journey system. In 48 patients (18 men and 30 women) with a mean age of 65 years (45 to 85) a tensor device was used to determine rotation. In the second group of 48 patients (14 men and 34 women) with a mean age of 64 years (41 to 86), an 'adapted' measured resection technique was used, taking into account the native rotational geometry of the femur as measured on a pre-operative CT scan. Both groups systematically reproduced a similar external rotation of the femoral component relative to the surgical transepicondylar axis: 2.4° (SD 2.5) in the gap-balancing group and 1.7° (SD 2.1) in the measured resection group (p = 0.134). Both gap-balancing and adapted measured resection techniques proved equally reliable and accurate in determining femoral component rotation after TKR. There was a tendency towards more external rotation in the gap-balancing group, but this difference was not statistically significant (p = 0.134). The number of outliers for our 'adapted' measured resection technique was much lower than reported in the literature.
获得平衡的屈曲间隙并使股骨组件正确旋转是全膝关节置换术(TKR)取得成功结果的前提条件之一。已经描述了实现这一目标的不同技术。在本研究中,我们前瞻性地比较了间隙平衡法与测量截骨法在使用Journey系统对96例患者进行的96例初次全膝关节置换术中确定股骨组件旋转的可靠性和准确性。在48例患者(18例男性和30例女性)中,平均年龄为65岁(45至85岁),使用张力装置来确定旋转。在第二组48例患者(14例男性和34例女性)中,平均年龄为64岁(41至86岁),采用了一种“改良”的测量截骨技术,该技术考虑了术前CT扫描测量的股骨原生旋转几何形状。两组均系统地重现了股骨组件相对于手术经髁轴的相似外旋角度:间隙平衡组为2.4°(标准差2.5),测量截骨组为1.7°(标准差2.1)(p = 0.134)。间隙平衡法和改良测量截骨法在全膝关节置换术后确定股骨组件旋转方面均被证明同样可靠和准确。间隙平衡组有更多外旋的趋势,但这种差异无统计学意义(p = 0.134)。我们“改良”测量截骨技术的异常值数量远低于文献报道。