Department of Ophthalmology, Medical University of Vienna, Vienna, Austria.
Curr Eye Res. 2013 Jan;38(1):86-90. doi: 10.3109/02713683.2012.717242. Epub 2012 Aug 31.
To compare the intensity of posterior capsule opacification (PCO) between two intraocular lenses (IOLs) of the same optic material, but with different haptic design (1-piece vs. 3-piece).
This prospective intraindividual controlled cohort study comprised eighty eyes of 40 patients with bilateral age-related cataract. Each patient received a Polylens Y10 (Polytech, Germany) 1-piece IOL in 1 eye and a Polylens Y30 (Polytech, Germany) 3-piece IOL in the contralateral eye. The IOL type in the first operated eye was randomly assigned before patient recruitment. Digital slitlamp photographs were taken 1 year postoperatively using a standardized photographic technique for regeneratory PCO. The amount of PCO was assessed subjectively at the slitlamp and objectively using automated image-analysis software.
The Polylens Y10 (1-piece) group showed significantly higher regeneratory and fibrotic PCO scores 1 year after surgery in subjective slitlamp evaluation, however not with objective evaluation using automated image-analysis software. Subjective PCO assessment resulted in a mean PCO score (scale = 0-10) of 1.6 in the Polylens Y10 group and 0.6 in the Polylens Y30 group at 1 year (p < 0.05). The mean automated image-analysis software PCO score was 1.5 in the Polylens Y10 group and 0.9 in the Polylens Y30 group (p = 0.6).
Both investigated IOLs showed good clinical performance regarding PCO, BCVA and IOL-centration. The Polylens Y10 IOL showed slightly more regeneratory PCO than the 3-piece acrylic IOL 1 year after surgery.
比较两种相同光学材料但具有不同襻设计(一体式与三件式)的人工晶状体(IOL)后囊混浊(PCO)的强度。
本前瞻性个体对照队列研究共纳入 40 例(80 只眼)年龄相关性白内障患者。每位患者的每只眼分别植入 Polytech 公司的 Polylens Y10 一体式 IOL 和 Polylens Y30 三件式 IOL。第一只手术眼的 IOL 类型在患者招募前随机分配。术后 1 年采用标准化照相技术拍摄数码裂隙灯照片,用于评估再生性 PCO。在裂隙灯显微镜下对 PCO 的量进行主观评估,并使用自动图像分析软件进行客观评估。
术后 1 年,在主观裂隙灯评估中,Poly-lens Y10(一体式)组的再生性和纤维性 PCO 评分明显更高,但使用自动图像分析软件的客观评估则不然。主观 PCO 评估显示,Poly-lens Y10 组术后 1 年的平均 PCO 评分为 1.6(范围为 0-10),而 Poly-lens Y30 组为 0.6(p<0.05)。Poly-lens Y10 组的平均自动图像分析软件 PCO 评分为 1.5,Poly-lens Y30 组为 0.9(p=0.6)。
两种研究 IOL 在 PCO、BCVA 和 IOL 中心方面均表现出良好的临床效果。术后 1 年,Poly-lens Y10 IOL 的再生性 PCO 略多于三件式丙烯酸 IOL。