Semmelweis University Budapest, faculty of Medicine, Department of Ophthalmology, Hungary.
J Refract Surg. 2012 Sep;28(9):645-9. doi: 10.3928/1081597X-20120823-01.
To evaluate corneal changes after corneal cross-linking (CXL) in progressive keratoconus with Scheimpflug imaging.
This prospective analysis included 40 eyes from 22 patients with progressive keratoconus. Corneal CXL was performed in 25 eyes (CXL group) and 15 fellow eyes served as controls (control group). Uncorrected (UDVA) and corrected distance visual acuity (CDVA), thinnest corneal thickness (ThCT), posterior elevation, and Holladay equivalent keratometry values (K1, K2) were determined with Pentacam (Oculus Optikgeräte GmbH) before and 1 year after CXL. Area under the receiver operator characteristic (ROC) curve and multivariable general estimating equation models were used to determine the most sensitive parameters of corneal changes.
Manifest sphere (-2.55±3.21 to -1.48±2.39 diopters [D], P=.02), UDVA (0.23±0.25 to 0.31±0.25, P<.001), and CDVA (0.58±0.28 to 0.72±0.19, P=.019) improved significantly in the CXL group. Significant decreases were found in ThCT (472.53±33.18 to 440.53±38.67 μm, P<.001), posterior elevation (68.33±28.69 to 22.67±16.21, P<.001), and keratometry values (K1 [45.06±4.55 to 43.51±4.67 D, P<.001], K2 [48.39±5.41 to 46.71±5.67 D, P<.001]) in the CXL group. These parameters remained stable in controls (P>.05). According to ROC analysis, posterior elevation change was the most characteristic parameter of corneal change after CXL (area under the curve=0.99). General estimating equation model showed that CXL (P=.001) and initial ThCT (P=.007) were significant predictors of decrease in posterior elevation with a significant negative interaction of initial ThCT on CXL effect (P=.005).
Posterior elevation is a sensitive parameter to monitor corneal remodeling after CXL. Corneal CXL showed augmented effect on corneal protrusion in eyes with thinner corneas.
应用 Scheimpflug 成像评估进展性圆锥角膜行角膜交联术(CXL)后的角膜变化。
本前瞻性分析纳入了 22 例 40 只眼进展性圆锥角膜患者。25 只眼行角膜 CXL(CXL 组),15 只对侧眼作为对照(对照组)。应用 Pentacam(Oculus Optikgeräte GmbH)于 CXL 术前及术后 1 年,分别检测未矫正(UDVA)和矫正视力(CDVA)、最薄角膜厚度(ThCT)、后表面高度(EH)和角膜曲率值(K1、K2)。受试者工作特征曲线(ROC)下面积和多变量广义估计方程模型用于确定角膜变化的最敏感参数。
CXL 组的临床球镜值(-2.55±3.21 至-1.48±2.39 屈光度 [D],P=.02)、UDVA(0.23±0.25 至 0.31±0.25,P<.001)和 CDVA(0.58±0.28 至 0.72±0.19,P=.019)显著提高。ThCT(472.53±33.18 至 440.53±38.67 μm,P<.001)、EH(68.33±28.69 至 22.67±16.21 μm,P<.001)和角膜曲率值(K1 [45.06±4.55 至 43.51±4.67 D,P<.001],K2 [48.39±5.41 至 46.71±5.67 D,P<.001])均显著降低。对照组上述参数均无明显变化(P>.05)。ROC 分析显示,EH 改变是 CXL 后角膜变化最具特征性的参数(曲线下面积=0.99)。广义估计方程模型显示,CXL(P=.001)和初始 ThCT(P=.007)是 EH 降低的显著预测因素,且初始 ThCT 对 CXL 效应有显著的负交互作用(P=.005)。
EH 是监测 CXL 后角膜重塑的敏感参数。对于角膜较薄的患者,角膜 CXL 对角膜隆起有增强作用。