Suppr超能文献

Scheimpflug 图像衍生的后表面高度在圆锥角膜和交联胶原角膜中的变异性。

Variability in Scheimpflug image-derived posterior elevation measurements in keratoconus and collagen-crosslinked corneas.

机构信息

Ophthalmology Department, University Hospital of Alexandroupolis, 68100 Dragana, Alexandroupolis, Greece.

出版信息

J Cataract Refract Surg. 2012 Sep;38(9):1616-25. doi: 10.1016/j.jcrs.2012.04.039.

Abstract

PURPOSE

To determine the variability in Scheimpflug image-derived posterior elevation measurements in eyes with keratoconus or corneal collagen crosslinking (CXL).

SETTING

Eye Institute of Thrace, Alexandroupolis, Greece.

DESIGN

Prospective observational study.

METHODS

Two operators in 2 sessions obtained posterior elevation measurements using the Pentacam Scheimpflug system. Variability in measurements was assessed using Bland-Altman analysis and intraclass correlation coefficients (ICCs). Measurements were associated with a series of Scheimpflug-derived keratoconus indices using the Pearson correlation and multivariate linear-regression analysis.

RESULTS

Mean interobserver differences for the central elevation point (e1) and the highest elevation point (HEP) in the keratoconus group were -0.9 μm (95% limits of agreement [LoA], 5.7 to -7.5 μm) and 1.7 μm (95% LoA, 26 to -22.6 μm), respectively. In the CXL group, the mean differences were 0.2 μm (95% LoA, 6.0 to -5.5 μm) and -6.1 μm (95% LoA, 16.8 to -29 μm), respectively. The ICC values in the keratoconus group were satisfactory for most elevation points; the ICC values were unsatisfactory for a series of points in the lower corneal hemisphere. The ICC values for points in both hemispheres were unsatisfactory in the CXL group; HEP had adequate reproducibility. The e1 and HEP parameters correlated significantly with most Scheimpflug-derived indices (P<.05) in the keratoconus group but not in the CXL group. Regression analysis indicated that the central keratoconus index was the primary determinant of the variability in keratoconus eyes.

CONCLUSIONS

Scheimpflug-derived posterior elevation measurements had acceptable reproducibility in keratoconus eyes and post-CXL eyes. Less consistent measurements were obtained in the lower hemisphere.

摘要

目的

确定圆锥角膜或角膜交联(CXL)眼中Scheimpflug 图像衍生的后表面隆起测量值的可变性。

地点

希腊亚历山德鲁波利斯色雷斯眼科研究所。

设计

前瞻性观察性研究。

方法

两名操作员在 2 个会话中使用 Pentacam Scheimpflug 系统获得后表面隆起测量值。使用 Bland-Altman 分析和组内相关系数(ICC)评估测量值的可变性。使用 Pearson 相关和多元线性回归分析将测量值与一系列 Scheimpflug 衍生的圆锥角膜指数相关联。

结果

在圆锥角膜组中,中央隆起点(e1)和最高隆起点(HEP)的观察者间平均差异分别为-0.9μm(95%置信区间[LoA],5.7 至-7.5μm)和 1.7μm(95%LoA,26 至-22.6μm)。在 CXL 组中,平均差异分别为 0.2μm(95%LoA,6.0 至-5.5μm)和-6.1μm(95%LoA,16.8 至-29μm)。圆锥角膜组中大多数隆起点的 ICC 值均令人满意;角膜下半部的一系列点的 ICC 值不理想。CXL 组中两个半球的 ICC 值均不理想;HEP 具有足够的可重复性。在圆锥角膜组中,e1 和 HEP 参数与大多数 Scheimpflug 衍生指数显著相关(P<.05),但在 CXL 组中则不然。回归分析表明,中央圆锥角膜指数是圆锥角膜眼变异的主要决定因素。

结论

圆锥角膜眼和 CXL 眼的 Scheimpflug 衍生后表面隆起测量值具有可接受的可重复性。下半部的测量值一致性较差。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验