Leppo J A, Meerdink D J
Department of Nuclear Medicine, University of Massachusetts Medical Center, Worcester 01655.
J Nucl Med. 1990 Jan;31(1):67-74.
The transcapillary exchange of a new class of 99mTc-labeled compounds (BATO) were compared to 201Tl in isolated, blood perfused rabbit hearts. During variable blood flow (0.15-2.44 ml/min/g), peak and net extraction (Emax and Enet, respectively), and capillary permeability-surface area product (PScap) were determined with paired indicator-dilution techniques. Serial bolus injections of 201Tl, [111In]albumin, and [99mTc]BATO; chloro[tris(cyclohexanedionedioxime)methyl boronic acid]Tc (SQ30217, n = 8) and a hydroxy-substituted derivative (SQ32014, n = 5) were given to a total of 13 hearts. Mean (+/- s.d.) SQ30217 Emax and Enet were 0.72 +/- 0.09 and 0.55 +/- 0.18, respectively, which were higher than thallium values of 0.57 +/- 0.10 and 0.46 +/- 0.17 (p less than 0.03). Mean SQ30217 PScap was 1.1 +/- 0.4 ml/min/g and was also higher than corresponding thallium determinations (0.7 +/- 0.3; p less than 0.001). SQ32014 Emax, Enet, and PScap were all significantly less than thallium values (p less than 0.001). Thallium and SQ30217 values for Emax and PScap were closely correlated with blood flow (r greater than or equal to 0.73), whereas those for SQ32014 were weakly correlated (r = 0.09). A small clinical pilot study (n = 3) was performed, which showed that SQ32014 was a poor myocardial perfusion agent in man. In summary, transcapillary exchange of SQ30217 is greater than thallium, which in turn, is greater than SQ32014. Therefore, SQ30217 appears to have good clinical potential, but SQ32014 does not.
在离体的、血液灌注的兔心脏中,将一类新型的99mTc标记化合物(BATO)的跨毛细血管交换与201Tl进行了比较。在可变血流量(0.15 - 2.44 ml/min/g)期间,采用配对指示剂稀释技术测定了峰值和净摄取量(分别为Emax和Enet)以及毛细血管通透性 - 表面积乘积(PScap)。对总共13颗心脏进行了201Tl、[111In]白蛋白和[99mTc]BATO的系列团注注射;氯[三(环己二酮二肟)甲基硼酸]Tc(SQ30217,n = 8)和一种羟基取代衍生物(SQ32014,n = 5)。SQ30217的平均(±标准差)Emax和Enet分别为0.72 ± 0.09和0.55 ± 0.18,高于铊的0.57 ± 0.10和0.46 ± 0.17(p < 0.03)。SQ30217的平均PScap为1.1 ± 0.4 ml/min/g,也高于相应的铊测定值(0.7 ± 0.3;p < 0.001)。SQ32014的Emax、Enet和PScap均显著低于铊值(p < 0.001)。铊和SQ30217的Emax和PScap值与血流量密切相关(r ≥ 0.73),而SQ32014的相关性较弱(r = 0.09)。进行了一项小型临床初步研究(n = 3),结果表明SQ32014在人体中是一种较差的心肌灌注剂。总之,SQ30217的跨毛细血管交换大于铊,而铊又大于SQ32014。因此,SQ30217似乎具有良好的临床潜力,但SQ32014则不然。