Abstract

BACKGROUND

Transpedicular stabilization of subaxial cervical spine is a very delicate procedure that requires thorough understanding of the pedicle anatomy to minimize the rate of neurovascular complications. The current study was conducted to investigate the morphometric details including dimensions and axis of typical cervical vertebrae (C3-C6) for transpedicular screw insertion surgery.

METHODS

The current study was conducted on 100 sides of 50 dry and 160 sides of 80 vertebrae on computerized tomography scans of typical cervical vertebrae. Parameters that were studied bilaterally included distance between medial aspect of the pedicle and dural sac, pedicle height, pedicle width, interpedicular distance, lateral and medial cortical thickness, transverse pedicle angle and chord length.

RESULTS

Distance between medial aspect of the pedicle and dural sac was found to be 2.2 ± 0.99 mm. Mean pedicle height (6.5 ± 1.1 mm) was found to be greater than pedicle width (4.9 ± 0.9 mm) in all the vertebrae. Mean transverse pedicle angle and chord length was observed to be 39.4° and 32.1 mm, respectively. Mean interpedicular distance, medial and lateral cortical thickness was observed to be 21.8 ± 1.6, 1.43 ± 0.4 and 0.79 ± 0.2 mm, respectively.

CONCLUSIONS

The present study highlights a three-dimensional orientation of subaxial cervical pedicle anatomy, while emphasizing the risks involved in the view of comparatively smaller values of pedicle dimensions of subaxial cervical vertebrae. This knowledge about typical cervical vertebrae, its pedicle and their adjacent neurovascular structures may enhance the safety of transpedicular screw insertion.

摘要

背景

下颈椎经椎弓根内固定术是一项非常精细的操作,需要深入了解椎弓根解剖结构,以尽量降低神经血管并发症的发生率。本研究旨在调查典型颈椎(C3 - C6)的形态学细节,包括尺寸和轴线,以用于经椎弓根螺钉植入手术。

方法

本研究对50具干燥颈椎的100侧以及80个椎体的160侧进行了典型颈椎的计算机断层扫描。双侧研究的参数包括椎弓根内侧缘与硬脊膜囊之间的距离、椎弓根高度、椎弓根宽度、椎弓根间距、外侧和内侧皮质厚度、椎弓根横角和弦长。

结果

发现椎弓根内侧缘与硬脊膜囊之间的距离为2.2 ± 0.99毫米。在所有椎体中,平均椎弓根高度(6.5 ± 1.1毫米)大于椎弓根宽度(4.9 ± 0.9毫米)。平均椎弓根横角和弦长分别为39.4°和32.1毫米。平均椎弓根间距、内侧和外侧皮质厚度分别为21.8 ± 1.6、1.43 ± 0.4和0.79 ± 0.2毫米。

结论

本研究突出了下颈椎椎弓根解剖结构的三维定向,同时鉴于下颈椎椎弓根尺寸相对较小,强调了其中涉及的风险。关于典型颈椎及其椎弓根以及相邻神经血管结构的这一知识可能会提高经椎弓根螺钉植入的安全性。