Suppr超能文献

评价手动和旋转器械技术在根管冠部止点预备中根管锉弯曲角度的影响。

Assessment of influence of flexion angles of files in apical stop preparation by using manual and rotary instrumentation techniques.

机构信息

Department of Endodontics, School of Dentistry, Federal University of Uberlândia, Uberlândia, Minas Gerais, Brazil.

出版信息

J Endod. 2012 Oct;38(10):1383-6. doi: 10.1016/j.joen.2012.06.041. Epub 2012 Aug 9.

Abstract

INTRODUCTION

This study aimed to evaluate the influence of flexion angles produced by files during root canal instrumentation on the final form of the apical stop.

METHODS

Sixty human lower incisors were divided into 3 groups (n = 20). After access preparation and working length determination, radiographs were taken from a mesiodistal and buccolingual direction with #15 K-file inserted to working length. Teeth from FlexM group were instrumented with stainless steel Flexofiles up to #40 file. For ProM and ProR groups, hand ProTaper Universal and ProTaper Universal rotary files were used, respectively, up to file F4. New radiographs were taken as previously described. After gutta-percha insertion, the apex of each specimen was ground, allowing gutta-percha visualization, and an image of the apex was captured to identify root canal deformation with computer software. The flexion of files was evaluated from both initial and final radiographs as the angle formed between the divergence of the file path and its virtual image represented by the direction taken by the file in the absence of curvature.

RESULTS

FlexM group presented the highest variation in flexion angles compared with ProM (P = .112) and ProR (P = .024) groups. Nickel-titanium rotary system (ProR) reduced apical stop deformation compared with the manual techniques that used nickel-titanium (P = .011) or stainless steel (P = .025) files.

CONCLUSIONS

Force vectors caused by the flexion angles of the files during the instrumentation of curved canals promoted apical stop deformation. ProTaper Universal rotary files showed less apical deformation than hand ProTaper Universal and stainless steel files.

摘要

简介

本研究旨在评估根管预备过程中锉的弯曲角度对根尖止点最终形态的影响。

方法

将 60 个人类下颌切牙分为 3 组(n = 20)。在建立直线通路和确定工作长度后,从近远中向和颊舌向分别拍摄 #15 K 锉插入工作长度的 X 光片。FlexM 组用不锈钢 Flexofiles 锉至 #40 锉。ProM 和 ProR 组分别用手动 ProTaper Universal 和 ProTaper Universal 机用镍钛锉锉至 F4。按上述方法再次拍摄 X 光片。牙胶尖插入后,每个样本的根尖被磨平,以便观察牙胶尖,并用计算机软件捕获根尖图像以识别根管变形。从初始和最终 X 光片评估锉的弯曲程度,即锉路径的发散角度与无曲率时锉的行进方向所代表的虚拟图像之间的角度。

结果

与 ProM(P =.112)和 ProR(P =.024)组相比,FlexM 组的弯曲角度变化最大。与使用镍钛(ProR)锉的手动技术相比,镍钛旋转锉(ProTaper Universal)技术减少了根尖止点变形(P =.011)。

结论

在弯曲根管预备过程中,锉的弯曲角度产生的力向量导致根尖止点变形。ProTaper Universal 机用镍钛锉比手动 ProTaper Universal 和不锈钢锉引起的根尖变形更小。