Olmedo-Buenrrostro Bertha Alicia, Jiménez-Herrera Carlos, Valadez-Meneses Rafael, Díaz-Giner Vicente R, Trujillo-Hernández Benjamín, Trujillo Xóchitl, Huerta Miguel, Delgado-Enciso Iván, Mora-Brambila Ana Bertha, Vásquez Clemente
Universidad de Colima, Centro Universitario de Investigaciones Biomédicas de Colima, Col. Villas de San Sebastián.
Rev Invest Clin. 2012 Mar-Apr;64(2):144-53.
Diseases of the musculoskeletal system are often accompanied by postural deformity or malalignment. Genu varo or genu valgo can be found in the knees. It is necessary to have a diagnostic support test for diagnosis as well as for follow-up of cases since these diseases are frequently progressive and over time have serious repercussions on patient quality of life. Objective. To evaluate a software program that processes digitalized photographs as a diagnostic test for measuring the mechanical axis in patients with genu varo and genu valgo.
The mechanical axis in both knees was measured by means of radiography (golden standard) and by means of a software program (proposed diagnostic test) in one hundred patients. Mechanical axis was considered to be abnormal when the angle was equal to or greater than four degrees. Sensitivity, specificity, positive predictive value, and negative predictive value were determined. Interobserver variation was evaluated with kappa statistics.
In relation to right knee genu varo, sensitivity, specificity, positive predictive value, and negative predictivie value were 0.84, 0.87, 0.84, and 0.87, respectively, and for the left knee values were 0.86, 0.87, 0.84, and 0.89, respectively. For genu valgo in the right knee, sensitivity, specificity, positive predictive value, and negative predictive value were 0.78, 0.98, 0.95, and 0.92, respectively, and in the left knee were 0.88, 0.95, 0.88, and 0.95, respectively. Kappa value was 0.9 in the right knee and 0.8 in the left knee.
The software program (diagnostic test) was useful for diagnosing genu varo or genu valgo, representing a safe and low-cost study.
肌肉骨骼系统疾病常伴有姿势畸形或排列不齐。膝内翻或膝外翻可出现在膝关节。由于这些疾病通常呈进行性发展,且随着时间推移会对患者生活质量产生严重影响,因此有必要进行诊断支持测试以用于诊断及病例随访。目的:评估一款处理数字化照片的软件程序,作为测量膝内翻和膝外翻患者机械轴的诊断测试。
对100例患者的双膝机械轴分别通过X线摄影(金标准)和一款软件程序(拟诊断测试)进行测量。当角度等于或大于4度时,机械轴被认为异常。确定敏感性、特异性、阳性预测值和阴性预测值。用kappa统计量评估观察者间差异。
对于右膝膝内翻,敏感性、特异性、阳性预测值和阴性预测值分别为0.84、0.87、0.84和0.87,左膝的值分别为0.86、0.87、0.84和0.89。对于右膝膝外翻,敏感性、特异性、阳性预测值和阴性预测值分别为0.78、0.98、0.95和0.92,左膝分别为0.88、0.95、0.88和0.95。右膝kappa值为0.9,左膝为0.8。
该软件程序(诊断测试)对诊断膝内翻或膝外翻有用,是一项安全且低成本的研究。