OBJECTIVE

Paired-pulse somatosensory evoked potentials (SEPs) are a common tool to investigate excitability in the human somatosensory cortex. Comparing literature about paired-pulse SEP, there is no standard set of stimulation parameters, while little is known about the influence of stimulation parameters on paired-pulse suppression.

METHODS

We analyzed changes of paired-pulse ratios by varying repetition rates from 1 to 9Hz, and using stimulus intensities of 250% of the sensory threshold and 100%, 120%, and 140% of the motor threshold, which are most frequently used in studies using paired-pulse SEPs.

RESULTS

We found a significant effect of repetition rate on paired-pulse suppression with increasing paired-pulse ratios from 1 to 9Hz, which is mainly caused by a change of single pulse amplitudes. We found no difference in paired-pulse suppression at the tested stimulation intensities.

CONCLUSIONS

The extent of paired-pulse ratios across different studies should be interpreted with caution due to the high dependence on repetition rate, while the results at the commonly used stimulus intensities are comparable.

SIGNIFICANCE

For an optimized parameter setting with sufficient paired-pulse suppression, we suggest a stimulation rate of 1 or 3Hz and a stimulation intensity of 250% of sensory threshold or slightly above motor threshold.

摘要

目的

成对脉冲体感诱发电位(SEP)是一种常用于研究人类体感皮层兴奋性的常用工具。在比较关于成对脉冲 SEP 的文献时,没有标准的刺激参数集,而对于刺激参数对成对脉冲抑制的影响知之甚少。

方法

我们通过从 1Hz 到 9Hz 改变重复率,并使用最常用于使用成对脉冲 SEP 的研究中的 250%感觉阈值和 100%、120%和 140%运动阈值的刺激强度,分析了成对脉冲比率的变化。

结果

我们发现重复率对成对脉冲抑制有显著影响,随着重复率从 1Hz 增加到 9Hz,成对脉冲比率逐渐增加,这主要是由于单脉冲幅度的变化所致。在测试的刺激强度下,我们没有发现成对脉冲抑制的差异。

结论

由于高度依赖于重复率,不同研究中不同的成对脉冲比率程度应该谨慎解释,而常用刺激强度下的结果是可比的。

意义

为了获得具有足够成对脉冲抑制的优化参数设置,我们建议刺激频率为 1Hz 或 3Hz,刺激强度为 250%感觉阈值或略高于运动阈值。